Lennox Heat pump XP17 Alert 411

What this problem usually means

Alert Code 411 in the XP17 table is 'Low pressure switch lockout', a critical alert: the low pressure switch has tripped repeatedly enough that the heat pump control has locked the compressor out rather than letting it keep starting into low pressure. It shares the pressure-fault causes and solutions Lennox prints for this table: restricted airflow over the indoor or outdoor coil, improper refrigerant charge, an improper or incorrectly operating metering device, and incorrect sensor location or connection, with checks of fan current draws, charge by approach and subcooling, and operating pressures against the charging charts. A lockout will not clear by waiting; the cause has to be found and corrected first.

Likely causes

  1. Refrigerant undercharge or leak causing repeated low-pressure trips
  2. Severely restricted indoor or outdoor airflow
  3. Metering device failed or badly restricted
  4. Pressure switch or sensor connection fault

How to fix it — step by step

  1. Record Alert 411 and do not repeatedly reset the system; each reset restarts the compressor into the same low-pressure condition that caused the lockout.
  2. Safety first: Turn the outdoor disconnect off and switch the breaker off, then verify the unit is dead with a meter before touching wiring; treat the run capacitor as charged and discharge it safely, because it can hold a charge after power is removed.
  3. Replace a clogged indoor filter and clear both coils, then remove the control-box panel to check the pressure switch and sensor connections for security, as the manual directs.
  4. A technician should measure operating pressures against the charging chart and verify charge by approach and subcooling, and check indoor and outdoor fan current draws; pressures that stay low with good airflow condemn the charge or metering device, while correct pressures condemn the switch or sensor path.
  5. Fix the proven cause, then reset once and run a full demand. Any refrigerant-side repair, charge adjustment or sealed-system work is EPA-certified-technician work only; do not open the refrigerant circuit yourself.

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix it

Parts run $5–$30

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.