Lennox ML14XP1 Common Problems

Find your problem in the list below. Each page explains the most likely causes, step-by-step checks you can do yourself, when to call a pro, and the parts that commonly resolve it. 4 problems covered.

Tap any code for its full fix — causes, step-by-step checks, and the parts that commonly fix it.

ProblemWhat it meansCheck first
Green LED (DS2) off, red LED (DS1) onTable 3 of the ML14XP1 instructions lists green off with red on, under Fault and Lockout Codes, as a low…Refrigerant leak or undercharge severe enough to trip the switch repeatedly›
Green LED (DS2) off, red LED (DS1) slow flashOn the ML14XP1 defrost control (CMC1), Table 3 of the Lennox installation instructions lists this DS2/DS1…Low refrigerant charge or a refrigerant leak›
Green LED (DS2) on, red LED (DS1) offTable 3 of the ML14XP1 instructions lists green on with red off as a high pressure switch lockout. The manual…Outdoor fan motor failed or its capacitor weak, so the coil cannot shed heat›
Green LED (DS2) slow flash, red LED (DS1) offOn the ML14XP1 defrost control (CMC1), Table 3 lists green slow flash with red off under Fault and Lockout…Outdoor fan not running or running weakly in cooling›

All Lennox heat pump models & codes →

Looking for a part?

Once you know the part you need, browse Lennox ML14XP1 replacement parts → The parts shelves are organized by brand, with the parts that actually fix these codes.