Lennox Heat pump XP17 Alert 414

What this problem usually means

Alert Code 414 in the XP17 table is 'Discharge line temperature fault'. Lennox's own explanation is precise: this code indicates high discharge temperatures, and if the discharge line temperature exceeds 279 degrees F (137 degrees C) during compressor operation, the control will de-energize the compressor contactor output (and the defrost output if active). The compressor remains off until the discharge temperature drops below 225 degrees F (107 degrees C). Discharge temperature that high means the compressor is overheating, commonly from low suction pressure, low charge or poor cooling of the compressor, and running through it risks oil breakdown and compressor failure, which is why the control stops the unit outright.

Likely causes

  1. Low refrigerant charge raising discharge superheat
  2. Low suction pressure from a restriction or metering problem
  3. Outdoor coil or airflow problem driving head pressure up
  4. Discharge sensor reading incorrectly

How to fix it — step by step

  1. Record Alert 414 and let the compressor cool; do not force restarts, because the control is holding it off until discharge temperature falls below 225 degrees F by design.
  2. Safety first: Turn the outdoor disconnect off and switch the breaker off, then verify the unit is dead with a meter before touching wiring; treat the run capacitor as charged and discharge it safely, because it can hold a charge after power is removed.
  3. Remove the control-box panel and locate the discharge line sensor on the compressor discharge line and the heat pump control (A175) it reports to; inspect its mounting and wiring.
  4. A technician should measure actual discharge line temperature and compare it with the sensor's report, and check suction pressure and charge; a genuinely hot discharge line points to charge or restriction, while a normal temperature with a 414 alert condemns the sensor or its connection.
  5. Correct the charge or restriction only through an EPA-certified technician; replace a proven-bad discharge sensor (thermistor) and confirm the unit runs without the temperature climbing back to the 279 degree trip.

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix it

Parts run $25–$80

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manual & model number

Find your model number on the outdoor unit's rating plate. It's the key to the right manual pages and the right parts.

Related Lennox Heat pump XP17 problems

See all Lennox XP17 codes & guides →