Lennox Heat pump XP17 Alert 400

What this problem usually means

The XP17 installation instructions (506586-01), Table 15, pair iComfort Touch thermostat Alert Code 400 with the condition 'Compressor internal overload trip'. The manual's cause column states the thermostat demand signal Y1 is present but the compressor is not running, and its solution column starts with the compressor protector being open, then checks for high head pressure and compressor supply voltage. In other words the compressor's internal overload has tripped and cut it out on temperature or current, and the system reports it instead of silently short-cycling. It clears after current is sensed in the run and start windings for two seconds, service is removed, or power is reset.

Likely causes

  1. Compressor internal overload open from high head pressure
  2. Outdoor unit power disconnect open
  3. Compressor circuit breaker tripped or fuse open
  4. Broken wire or poor connector in the compressor circuit
  5. Compressor contactor failed to close

How to fix it — step by step

  1. Record Alert 400 and whether Y1 was calling before cycling power; note if the compressor is hot, because an internal overload needs time to cool and reset.
  2. Safety first: Turn the outdoor disconnect off and switch the breaker off, then verify the unit is dead with a meter before touching wiring; treat the run capacitor as charged and discharge it safely, because it can hold a charge after power is removed.
  3. Remove the outdoor control-box panel to reach the heat pump control (A175), the compressor contactor (K1) and the capacitor (C12) shown in the manual's parts arrangement.
  4. Check the disconnect and breaker are closed, confirm supply voltage at the contactor, and test whether the contactor pulls in on a call; a technician should also check head pressure, because the manual ties this trip to high head pressure. Voltage present with the contactor closed but no compressor current points back to the open internal overload or a compressor fault.
  5. Let a tripped overload cool, correct any high-pressure or power cause found, and replace a proven-bad contactor; compressor-internal faults are a pro repair. Run one demand and confirm current is sensed and the alert clears.

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix it

Parts run $10–$35

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manual & model number

Find your model number on the outdoor unit's rating plate. It's the key to the right manual pages and the right parts.