Lennox Heat pump XP17 Alert 415
What this problem usually means
Alert Code 415 in the XP17 table is 'Discharge line temperature lockout', a critical alert: the high discharge temperature condition behind Alert 414 has happened severely or repeatedly enough that the control has locked the unit out instead of letting it restart when the line cools below 225 degrees F. The underlying physics is the same as the fault: discharge temperature above 279 degrees F (137 degrees C) during compressor operation, which Lennox says de-energizes the compressor contactor and any active defrost output. A lockout version means the overheating cause, usually low charge, a restriction or failing compressor cooling, is still present and must be diagnosed, not reset away.
Likely causes
- Low refrigerant charge or a leak
- Refrigerant restriction starving the compressor
- Failing compressor running hot
- Discharge sensor fault falsely reporting high temperature
How to fix it — step by step
- Record Alert 415 and leave the unit off; repeated lockout resets on an overheating compressor can finish it.
- Safety first: Turn the outdoor disconnect off and switch the breaker off, then verify the unit is dead with a meter before touching wiring; treat the run capacitor as charged and discharge it safely, because it can hold a charge after power is removed.
- Locate the discharge line sensor and the heat pump control (A175) in the control box and inspect the sensor's clip mounting on the discharge line and its wiring for damage.
- A technician should verify real discharge temperature against the sensor reading, then check suction and discharge pressures and charge; real overheating with low suction points to charge or restriction, while normal temperatures condemn the sensor circuit.
- Repair the proven cause; sealed-system work is EPA-certified-technician work only. Reset once after repair and monitor a full run for temperature stability.
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the Thermistor.
Parts that commonly fix it
- Thermistor$25–$80Shop at Amazon
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number on the outdoor unit's rating plate. It's the key to the right manual pages and the right parts.