Goodman Heat pump Error Codes
Find your code in the list below. Each page explains what the code means, the most likely causes, step-by-step fixes you can do yourself, and the parts that commonly resolve it. 21 codes covered.
Finding your model number: it is on the outdoor unit's rating plate.
Tap any code for its full fix — causes, step-by-step checks, and the parts that commonly fix it.
ComfortBridge condensing units (7-segment codes)
Codes show on the integrated control module's 7-segment LED display behind the outdoor unit's control access panel - the first digit reads blank. In standby, the RECALL button replays the six most recent faults.
| Code | What it means | Check first | |
|---|---|---|---|
| 01 | Read on the integrated control module's 7-segment LED display behind the outdoor unit's control access panel… | Low refrigerant charge | › |
| 02 | Read on the integrated control module's 7-segment LED display behind the outdoor unit's control access panel… | Blocked / dirty condenser (outdoor) coil | › |
| 03 | Read on the integrated control module's 7-segment LED display behind the outdoor unit's control access panel… | Intermittent thermostat demand | › |
| 04 | Read on the integrated control module's 7-segment LED display behind the outdoor unit's control access panel… | Compressor bearings seized (locked rotor) | › |
| 05 | Read on the integrated control module's 7-segment LED display behind the outdoor unit's control access panel… | Power disconnected / breaker or fuse open | › |
| 06 | Read on the integrated control module's 7-segment LED display behind the outdoor unit's control access panel… | Compressor start winding open | › |
| A2 | Read on the integrated control module's 7-segment LED display behind the outdoor unit's control access panel… | Shorted outdoor air temperature sensor | › |
| A3 | Read on the integrated control module's 7-segment LED display behind the outdoor unit's control access panel… | Shorted outdoor coil temperature sensor | › |
| b0 | Read on the integrated control module's 7-segment LED display behind the outdoor unit's control access panel… | Indoor blower motor problem | › |
| b9 | Read on the integrated control module's 7-segment LED display behind the outdoor unit's control access panel… | Blocked / dirty air filter | › |
| d0 | Read on the integrated control module's 7-segment LED display behind the outdoor unit's control access panel… | Control module contains no shared data for a communicating installation | › |
| d1 | Read on the integrated control module's 7-segment LED display behind the outdoor unit's control access panel… | Invalid shared data loaded in the control module | › |
| d2 | Read on the integrated control module's 7-segment LED display behind the outdoor unit's control access panel… | Outdoor unit requires more airflow than the indoor unit can supply | › |
| d3 | Read on the integrated control module's 7-segment LED display behind the outdoor unit's control access panel… | Shared data does not match the control's hardware configuration | › |
| d4 | Read on the integrated control module's 7-segment LED display behind the outdoor unit's control access panel… | Shared data on the BTSDL01 rejected by the control | › |
| E5 | Read on the integrated control module's 7-segment LED display behind the outdoor unit's control access panel… | Short in the low-voltage (24 VAC) wiring | › |
| EE | Read on the integrated control module's 7-segment LED display behind the outdoor unit's control access panel… | Compressor relay contacts welded on the control board | › |
| H8 | Read on the integrated control module's 7-segment LED display behind the outdoor unit's control access panel… | High line voltage from the utility supply (above 255 VAC) | › |
| L1 | Read on the integrated control module's 7-segment LED display behind the outdoor unit's control access panel… | Low refrigerant charge | › |
| L2 | Read on the integrated control module's 7-segment LED display behind the outdoor unit's control access panel… | Blocked / dirty condenser (outdoor) coil | › |
| L8 | Read on the integrated control module's 7-segment LED display behind the outdoor unit's control access panel… | Low line voltage (below 185 VAC) | › |
Common questions
Where do I read a Goodman heat pump fault code?
On the integrated control module inside the outdoor unit: remove the control-box access panel and read the 7-segment LED display (the chart prints the first digit as blank). With the thermostat idle, holding the RECALL button for 2-5 seconds replays the six most recent faults.
What does b9 mean on a Goodman heat pump?
Airflow is lower than demanded. The ComfortBridge chart lists b9 as an airflow fault: the system keeps running at reduced capacity while the delivered airflow stays below what the control is asking for.
Once you know the part you need, browse Goodman Heat pump replacement parts → The parts shelves are organized by brand, with the parts that actually fix these codes.