Goodman Heat pump Error Codes

Find your code in the list below. Each page explains what the code means, the most likely causes, step-by-step fixes you can do yourself, and the parts that commonly resolve it. 21 codes covered.

Finding your model number: it is on the outdoor unit's rating plate.

Tap any code for its full fix — causes, step-by-step checks, and the parts that commonly fix it.

ComfortBridge condensing units (7-segment codes)

Codes show on the integrated control module's 7-segment LED display behind the outdoor unit's control access panel - the first digit reads blank. In standby, the RECALL button replays the six most recent faults.

CodeWhat it meansCheck first
01Read on the integrated control module's 7-segment LED display behind the outdoor unit's control access panel…Low refrigerant charge›
02Read on the integrated control module's 7-segment LED display behind the outdoor unit's control access panel…Blocked / dirty condenser (outdoor) coil›
03Read on the integrated control module's 7-segment LED display behind the outdoor unit's control access panel…Intermittent thermostat demand›
04Read on the integrated control module's 7-segment LED display behind the outdoor unit's control access panel…Compressor bearings seized (locked rotor)›
05Read on the integrated control module's 7-segment LED display behind the outdoor unit's control access panel…Power disconnected / breaker or fuse open›
06Read on the integrated control module's 7-segment LED display behind the outdoor unit's control access panel…Compressor start winding open›
A2Read on the integrated control module's 7-segment LED display behind the outdoor unit's control access panel…Shorted outdoor air temperature sensor›
A3Read on the integrated control module's 7-segment LED display behind the outdoor unit's control access panel…Shorted outdoor coil temperature sensor›
b0Read on the integrated control module's 7-segment LED display behind the outdoor unit's control access panel…Indoor blower motor problem›
b9Read on the integrated control module's 7-segment LED display behind the outdoor unit's control access panel…Blocked / dirty air filter›
d0Read on the integrated control module's 7-segment LED display behind the outdoor unit's control access panel…Control module contains no shared data for a communicating installation›
d1Read on the integrated control module's 7-segment LED display behind the outdoor unit's control access panel…Invalid shared data loaded in the control module›
d2Read on the integrated control module's 7-segment LED display behind the outdoor unit's control access panel…Outdoor unit requires more airflow than the indoor unit can supply›
d3Read on the integrated control module's 7-segment LED display behind the outdoor unit's control access panel…Shared data does not match the control's hardware configuration›
d4Read on the integrated control module's 7-segment LED display behind the outdoor unit's control access panel…Shared data on the BTSDL01 rejected by the control›
E5Read on the integrated control module's 7-segment LED display behind the outdoor unit's control access panel…Short in the low-voltage (24 VAC) wiring›
EERead on the integrated control module's 7-segment LED display behind the outdoor unit's control access panel…Compressor relay contacts welded on the control board›
H8Read on the integrated control module's 7-segment LED display behind the outdoor unit's control access panel…High line voltage from the utility supply (above 255 VAC)›
L1Read on the integrated control module's 7-segment LED display behind the outdoor unit's control access panel…Low refrigerant charge›
L2Read on the integrated control module's 7-segment LED display behind the outdoor unit's control access panel…Blocked / dirty condenser (outdoor) coil›
L8Read on the integrated control module's 7-segment LED display behind the outdoor unit's control access panel…Low line voltage (below 185 VAC)›

Common questions

Where do I read a Goodman heat pump fault code?
On the integrated control module inside the outdoor unit: remove the control-box access panel and read the 7-segment LED display (the chart prints the first digit as blank). With the thermostat idle, holding the RECALL button for 2-5 seconds replays the six most recent faults.

What does b9 mean on a Goodman heat pump?
Airflow is lower than demanded. The ComfortBridge chart lists b9 as an airflow fault: the system keeps running at reduced capacity while the delivered airflow stays below what the control is asking for.

Looking for a part?

Once you know the part you need, browse Goodman Heat pump replacement parts → The parts shelves are organized by brand, with the parts that actually fix these codes.