Goodman Heat pump ComfortBridge heat pump condensing units d4 Error Code

What the d4 code means

Read on the integrated control module's 7-segment LED display behind the outdoor unit's control access panel (first digit blank), this is the chart's 'Invalid Shared Data' fault, with the symptom that the heat pump fails to operate. The manual states the shared data on the BTSDL01 has been rejected. Corrective actions are to verify the system type, verify the shared data is correct for the specific model and repopulate it if required, or wire the system as a legacy system. In other words the control refused the data set offered to it, so the data - or the device carrying it - is the suspect, not the refrigerant circuit.

Likely causes

  1. Shared data on the BTSDL01 rejected by the control
  2. Shared data not correct for this specific model
  3. Faulty shared-data device

How to fix it — step by step

  1. Record the code before cycling power: remove the outdoor unit's control-box access panel and read all three 7-segment LED digits on the integrated control module (the chart prints the first digit as BLANK), and also use the RECALL push button in Standby (no thermostat demand, press 2-5 seconds) to note the six most recent faults, so d4 is not lost when power is cycled.
  2. Safety: switch the thermostat off, open the outdoor disconnect and the breaker, verify 0 VAC line-to-line and line-to-ground at the contactor with a meter before touching wiring, and treat the run capacitor as charged - discharge it through a resistor and re-verify 0 V before handling it.
  3. Locate the part: the BTSDL01 shared-data device and the integrated control module it plugs into, inside the outdoor unit's control box behind the control access panel.
  4. Test: confirm the data set on the device is the one for this exact model - data for another model explains the rejection outright. Try loading with the device inserted BEFORE power is turned on, as the manual requires; a correct-model data set that is still rejected on a correctly timed load points to a faulty data device or control input.
  5. End at the fix: load the correct model-specific shared data (replacing the data device if it is faulty), restore power and confirm d4 clears once data is accepted; if a known-good device with correct data is still rejected, replace the Control board. → Shop the control board at Amazon

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix the d4 code

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manufacturer documentation

Manual & model number

Working on a specific model? The official Goodman manual is on Goodman's support site — you'll need your model number.

Find your model number on the outdoor unit's rating plate. It's the key to the right manual pages and the right parts.

Related Goodman Heat pump ComfortBridge heat pump condensing units error codes

See all Goodman ComfortBridge heat pump condensing units codes & guides →