Goodman Heat pump ComfortBridge heat pump condensing units EE Error Code

What the EE code means

Read on the integrated control module's 7-segment LED display behind the outdoor unit's control access panel (first digit blank), this is the chart's 'Board misoperation,' with the symptom that the air conditioner/heat pump fails to operate. The manual's listed cause is compressor relay contacts welded, and its corrective action is simply to replace the control. Welded relay contacts mean the board can no longer switch the compressor circuit as commanded, so the control itself - not a field-replaceable relay - is the condemned part when this code is set.

Likely causes

  1. Compressor relay contacts welded on the control board
  2. Internal control board misoperation

How to fix it — step by step

  1. Record the code before cycling power: remove the outdoor unit's control-box access panel and read all three 7-segment LED digits on the integrated control module (the chart prints the first digit as BLANK), and also use the RECALL push button in Standby (no thermostat demand, press 2-5 seconds) to note the six most recent faults, so EE is not lost when power is cycled.
  2. Safety: switch the thermostat off, open the outdoor disconnect and the breaker, verify 0 VAC line-to-line and line-to-ground at the contactor with a meter before touching wiring, and treat the run capacitor as charged - discharge it through a resistor and re-verify 0 V before handling it.
  3. Locate the part: the integrated control module (the outdoor Control board carrying the 7-segment display, TEST and RECALL buttons) is mounted in the outdoor unit's control box behind the control access panel; the welded compressor relay is soldered on that board and is not serviced separately.
  4. Test: with power off and demand removed, check for continuity through the board's compressor relay output when it should be open - continuity with no call proves welded contacts. Also verify the board is receiving its 24 VAC supply, because a board with correct supply power that still displays EE has failed internally.
  5. End at the fix: replace the Control board with the correct replacement part, restore power, and run heating and cooling calls to confirm the compressor starts and stops on command and EE does not return; no other part is condemned by this code.

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix the EE code

  • Control boardShop at Amazon
  • Tools for this job, if you need them$15–$65

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manufacturer documentation

Manual & model number

Working on a specific model? The official Goodman manual is on Goodman's support site — you'll need your model number.

Find your model number on the outdoor unit's rating plate. It's the key to the right manual pages and the right parts.

Related Goodman Heat pump ComfortBridge heat pump condensing units error codes

See all Goodman ComfortBridge heat pump condensing units codes & guides →