Goodman Heat pump ComfortBridge heat pump condensing units 05 Error Code
What the 05 code means
Read on the integrated control module's 7-segment LED display behind the outdoor unit's control access panel (first digit blank), this is the chart's 'Open Circuit' fault: power has been disconnected for greater than 4 hours, with the low and high pressure switches closed, and compressor and outdoor fan are off. The manual lists power disconnected, a failed compressor protector, or the compressor not properly wired to the control. Corrective actions are to check circuit breakers and fuses, check the wiring to the unit, and check the compressor and its wiring, repairing or replacing as needed.
Likely causes
- Power disconnected / breaker or fuse open
- Failed compressor protector
- Compressor not properly wired to the control
- Faulty compressor wiring
How to fix it — step by step
- Record the code before cycling power: remove the outdoor unit's control-box access panel and read all three 7-segment LED digits on the integrated control module (the chart prints the first digit as BLANK), and also use the RECALL push button in Standby (no thermostat demand, press 2-5 seconds) to note the six most recent faults, so 05 is not lost when power is cycled.
- Safety: switch the thermostat off, open the outdoor disconnect and the breaker, verify 0 VAC line-to-line and line-to-ground at the contactor with a meter before touching wiring, and treat the run capacitor as charged - discharge it through a resistor and re-verify 0 V before handling it.
- Locate the part: check the breaker/fuse and outdoor disconnect first, then the integrated control module and compressor wiring in the outdoor unit's control box and compressor terminal area, reached through the unit's access panels; the code is read on that same control module.
- Test: meter line voltage at the disconnect and at the contactor - absent voltage proves the supply side (breaker, fuse, disconnect or wiring to the unit), while correct voltage present moves the test to the compressor circuit: with power off, check continuity of the compressor protector and the compressor wiring to the control, where an open protector or broken lead is the pinpoint.
- End at the fix: restore the supply fault or repair/replace the faulty wiring or protector as the tests condemn, restore power and run a call - the fault clears after 1 normal cycle or by cycling 24 VAC to the control; internal compressor faults beyond the protector are certified-technician work.
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
Then the fault is internal - there is no documented owner fix beyond the steps above. If you're not comfortable taking it apart yourself, a repair shop is the next step.
Parts that commonly fix the 05 code
No specific replacement part is documented for this fault. If the checks above do not clear it, your heat pump likely needs to be disassembled and an internal part replaced - and since the manufacturer publishes no procedure for that, it is the point where most owners hand it to a repair shop.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Working on a specific model? The official Goodman manual is on Goodman's support site — you'll need your model number.
Find your model number on the outdoor unit's rating plate. It's the key to the right manual pages and the right parts.
Related Goodman Heat pump ComfortBridge heat pump condensing units error codes
See all Goodman ComfortBridge heat pump condensing units codes & guides →