Goodman Heat pump ComfortBridge heat pump condensing units A2 Error Code
What the A2 code means
Read on the integrated control module's 7-segment LED display behind the outdoor unit's control access panel (first digit blank), this is the chart's 'Outdoor air temp sensor fault.' The manual lists a shorted sensor, an open sensor, a disconnected sensor or a sensor out of range, and its corrective action is to check the sensor connection and replace an open or shorted sensor. The outdoor air sensor feeds the control's heating, defrost and ambient decisions, so a bad reading can stop or mis-time heat-pump operation even though the refrigerant circuit itself is healthy.
Likely causes
- Shorted outdoor air temperature sensor
- Open outdoor air temperature sensor
- Sensor disconnected at the control board
- Sensor out of range / drifted out of calibration
How to fix it — step by step
- Record the code before cycling power: remove the outdoor unit's control-box access panel and read all three 7-segment LED digits on the integrated control module (the chart prints the first digit as BLANK), and also use the RECALL push button in Standby (no thermostat demand, press 2-5 seconds) to note the six most recent faults, so A2 is not lost when power is cycled.
- Safety: switch the thermostat off, open the outdoor disconnect and the breaker, verify 0 VAC line-to-line and line-to-ground at the contactor with a meter before touching wiring, and treat the run capacitor as charged - discharge it through a resistor and re-verify 0 V before handling it.
- Locate the part: the outdoor air temperature sensor (a small thermistor on a two-wire lead) is mounted at the outdoor unit where it samples ambient air, with its harness plugged into the integrated control module inside the control box; access is through the control access panel.
- Test: with power off, unplug the sensor and measure its resistance with a multimeter and compare it with the temperature around the unit - an open circuit (OL) proves an open sensor or broken lead, and a near-zero reading proves a short; either result condemns the sensor rather than the board.
- End at the fix: replace a sensor that tests open, shorted or far out of range, reseat a merely disconnected plug, restore power and confirm A2 does not return; if a known-good sensor still produces A2, the pinpointed cause is the control board's sensor input - replace the Control board. → Shop the control board at Amazon
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
Then the likely broken part is the Thermistor.
Also tied to this fault: Control board - Shop at Amazon
Parts that commonly fix the A2 code
- Thermistor$25–$80Shop at Amazon
- Control boardShop at Amazon
- Tools for this job, if you need them$15–$65
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Working on a specific model? The official Goodman manual is on Goodman's support site — you'll need your model number.
Find your model number on the outdoor unit's rating plate. It's the key to the right manual pages and the right parts.