Goodman Heat pump ComfortBridge heat pump condensing units L1 Error Code

What the L1 code means

Read on the integrated control module's 7-segment LED display behind the outdoor unit's control access panel (first digit blank), L1 is the chart's 'Low Pressure Cut Out Lockout (3 Trips)': the low pressure switch has tripped three times within the same thermostat demand, and the compressor and outdoor fan are off while demand is still present. The manual's causes are the same low-side list as code 01 - low refrigerant charge, a restriction in the liquid line, indoor blower motor failure, or the thermostat set extremely low - and it adds checking the low pressure switch itself. Unlike a single trip, L1 will not self-clear: the fault must be cleared by cycling 24 VAC to the control.

Likely causes

  1. Low refrigerant charge
  2. Restriction in the liquid line
  3. Indoor blower motor failure
  4. Faulty low pressure switch
  5. Indoor thermostat set extremely low

How to fix it — step by step

  1. Record the code before cycling power: remove the outdoor unit's control-box access panel and read all three 7-segment LED digits on the integrated control module (the chart prints the first digit as BLANK), and also use the RECALL push button in Standby (no thermostat demand, press 2-5 seconds) to note the six most recent faults, so L1 is not lost when power is cycled.
  2. Safety: switch the thermostat off, open the outdoor disconnect and the breaker, verify 0 VAC line-to-line and line-to-ground at the contactor with a meter before touching wiring, and treat the run capacitor as charged - discharge it through a resistor and re-verify 0 V before handling it.
  3. Locate the part: the low pressure switch is on the suction/low-side refrigerant line inside the outdoor unit, reached by removing the unit's access panel; the code is read on the integrated control module in the control box, and the indoor blower check is at the air handler.
  4. Test: prove indoor airflow first (blower running, filter clean) and check the thermostat setting, then, with power off, test the low pressure switch for continuity appropriate to a system at rest pressure - a switch open on a charged, resting system is faulty. Sealed-system pressure/charge verification itself is gauge work for a certified technician.
  5. End at the pinpoint: replace a low pressure switch that tests faulty, or repair/replace a failed indoor blower; if switch and airflow are proven good, the pinpoint is low charge or a liquid-line restriction, fixed only by an EPA-certified technician, after which the lockout is cleared by cycling 24 VAC to the control.

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix the L1 code

No specific replacement part is documented for this fault. If the checks above do not clear it, your heat pump likely needs to be disassembled and an internal part replaced - and since the manufacturer publishes no procedure for that, it is the point where most owners hand it to a repair shop.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manufacturer documentation

Manual & model number

Working on a specific model? The official Goodman manual is on Goodman's support site — you'll need your model number.

Find your model number on the outdoor unit's rating plate. It's the key to the right manual pages and the right parts.

Related Goodman Heat pump ComfortBridge heat pump condensing units error codes

See all Goodman ComfortBridge heat pump condensing units codes & guides →