Goodman Heat pump ComfortBridge heat pump condensing units d2 Error Code

What the d2 code means

Read on the integrated control module's 7-segment LED display behind the outdoor unit's control access panel (first digit blank), this is the chart's 'System Mis-Match' fault: the heat pump fails to operate, operates at reduced performance, or runs at low stage when high stage is expected. The manual explains the outdoor unit requires airflow greater than the indoor unit's airflow capability, or the shared data is incompatible with the system or missing parameters. Corrective actions are to verify the system type, verify and repopulate the shared data for the specific model, or wire the system as a legacy system.

Likely causes

  1. Outdoor unit requires more airflow than the indoor unit can supply
  2. Shared data incompatible with the system
  3. Shared data missing parameters
  4. Indoor and outdoor units not an approved match

How to fix it — step by step

  1. Record the code before cycling power: remove the outdoor unit's control-box access panel and read all three 7-segment LED digits on the integrated control module (the chart prints the first digit as BLANK), and also use the RECALL push button in Standby (no thermostat demand, press 2-5 seconds) to note the six most recent faults, so d2 is not lost when power is cycled.
  2. Safety: switch the thermostat off, open the outdoor disconnect and the breaker, verify 0 VAC line-to-line and line-to-ground at the contactor with a meter before touching wiring, and treat the run capacitor as charged - discharge it through a resistor and re-verify 0 V before handling it.
  3. Locate the part: no single failed part is indicated - compare the outdoor unit's rating plate (behind/above the control access panel area) with the indoor unit's rating plate at the air handler, and access the integrated control module in the outdoor control box to check its shared data.
  4. Test: compare the two rating plates and the specification sheets for approved system matches - an indoor unit whose maximum airflow is below the outdoor unit's requirement proves the mismatch. If the pairing is approved, check that the shared data in the control is correct for this specific model; wrong data on a matched pair is a data fault, not a hardware fault.
  5. End at the fix: repopulate the correct shared data if the pairing is approved, or correct the equipment pairing to an approved match if it is not, then restore power and confirm the system runs at high stage without d2; data and pairing work only - no part is condemned by d2 itself.

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix the d2 code

This fault usually does not need a replacement part - the fix is in the steps above. If your heat pump does need a part, start with the link above.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manufacturer documentation

Manual & model number

Working on a specific model? The official Goodman manual is on Goodman's support site — you'll need your model number.

Find your model number on the outdoor unit's rating plate. It's the key to the right manual pages and the right parts.

Related Goodman Heat pump ComfortBridge heat pump condensing units error codes

See all Goodman ComfortBridge heat pump condensing units codes & guides →