Goodman Heat pump ComfortBridge heat pump condensing units b0 Error Code

What the b0 code means

Read on the integrated control module's 7-segment LED display behind the outdoor unit's control access panel (first digit blank), this is the chart's fault for the circulator blower motor not running when it should be running, with the symptom that the air conditioner/heat pump fails to operate. The manual lists an indoor blower motor problem or a communications error between the indoor and outdoor unit, and notes it applies only to a fully communicating system. Without indoor airflow the outdoor unit is held off to protect the coil and compressor.

Likely causes

  1. Indoor blower motor problem
  2. Communications error between indoor and outdoor unit
  3. Faulty indoor blower motor wiring
  4. Faulty indoor unit control

How to fix it — step by step

  1. Record the code before cycling power: remove the outdoor unit's control-box access panel and read all three 7-segment LED digits on the integrated control module (the chart prints the first digit as BLANK), and also use the RECALL push button in Standby (no thermostat demand, press 2-5 seconds) to note the six most recent faults, so b0 is not lost when power is cycled.
  2. Safety: switch the thermostat off, open the outdoor disconnect and the breaker, verify 0 VAC line-to-line and line-to-ground at the contactor with a meter before touching wiring, and treat the run capacitor as charged - discharge it through a resistor and re-verify 0 V before handling it.
  3. Locate the part: this fault points indoors - the circulator blower motor and indoor unit control are in the air handler/furnace, reached through its blower access panel, while the code itself is read on the outdoor integrated control module behind the outdoor control access panel.
  4. Test: verify the indoor unit has line power and 24 VAC control power, inspect the blower motor wiring, and check whether the blower runs on a fan-only call - a blower that never runs with correct power and a valid call condemns the motor or indoor control, while a running blower with b0 persisting points to the indoor-outdoor communications wiring.
  5. End at the fix: repair any faulty wiring, or repair/replace the indoor blower motor or indoor control as the tests condemn, then restore power and confirm the blower runs on demand and b0 clears; this code does not condemn an outdoor part.

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix the b0 code

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manufacturer documentation

Manual & model number

Working on a specific model? The official Goodman manual is on Goodman's support site — you'll need your model number.

Find your model number on the outdoor unit's rating plate. It's the key to the right manual pages and the right parts.