Goodman Heat pump ComfortBridge heat pump condensing units E5 Error Code

What the E5 code means

Read on the integrated control module's 7-segment LED display behind the outdoor unit's control access panel (first digit blank), this is the chart's 'Open fuse,' with the symptom that the air conditioner/heat pump fails to operate. The manual's only listed cause is a short in the low-voltage wiring, and its corrective action is to locate and correct that short and replace the fuse with a 3-amp automotive type. The fuse protects the 24 VAC control circuit, so E5 means control power is lost until both the short and the fuse are dealt with.

Likely causes

  1. Short in the low-voltage (24 VAC) wiring
  2. Chafed thermostat/control wire shorting to ground or another conductor
  3. Shorted low-voltage component fed through the board fuse

How to fix it — step by step

  1. Record the code before cycling power: remove the outdoor unit's control-box access panel and read all three 7-segment LED digits on the integrated control module (the chart prints the first digit as BLANK), and also use the RECALL push button in Standby (no thermostat demand, press 2-5 seconds) to note the six most recent faults, so E5 is not lost when power is cycled.
  2. Safety: switch the thermostat off, open the outdoor disconnect and the breaker, verify 0 VAC line-to-line and line-to-ground at the contactor with a meter before touching wiring, and treat the run capacitor as charged - discharge it through a resistor and re-verify 0 V before handling it.
  3. Locate the part: the 3-amp automotive-type blade fuse sits on the integrated control module inside the outdoor unit's control box, reached by removing the control access panel; the low-voltage wiring it protects runs from that board toward the indoor unit and thermostat.
  4. Test: with power off, pull the fuse and check it for continuity - no continuity confirms it is open, which only proves the fuse blew, not why. Then inspect and ohm out the low-voltage runs for a short to ground or between conductors; a low resistance to ground pinpoints the shorted run.
  5. End at the fix: repair or replace the shorted low-voltage wiring first, then fit a new 3-amp automotive-type fuse, restore power and run a call - if the new fuse holds and E5 clears, the short was the cause; a fuse that blows again with wiring proven good pinpoints a shorted board-level load, so replace the Control board. → Shop the control board at Amazon

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix the E5 code

  • Control boardShop at Amazon
  • Tools for this job, if you need them$15–$65

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manufacturer documentation

Manual & model number

Working on a specific model? The official Goodman manual is on Goodman's support site — you'll need your model number.

Find your model number on the outdoor unit's rating plate. It's the key to the right manual pages and the right parts.

Related Goodman Heat pump ComfortBridge heat pump condensing units error codes

See all Goodman ComfortBridge heat pump condensing units codes & guides →