Goodman Heat pump ComfortBridge heat pump condensing units 06 Error Code
What the 06 code means
Read on the integrated control module's 7-segment LED display behind the outdoor unit's control access panel (first digit blank), this is the chart's 'Open Start Circuit' fault, with compressor and outdoor fan off and the low and high pressure switches closed. The manual lists a compressor start winding that is open, a failed compressor run capacitor, faulty run capacitor wiring, the compressor not properly wired to the control, or faulty compressor wiring. Corrective actions are to check the compressor, check and replace the run capacitor as needed, and check the wiring. In short, the control can see the run circuit but the start path needed to get the compressor turning is open somewhere.
Likely causes
- Compressor start winding open
- Failed compressor run capacitor
- Faulty run capacitor wiring
- Compressor not properly wired to the control
How to fix it — step by step
- Record the code before cycling power: remove the outdoor unit's control-box access panel and read all three 7-segment LED digits on the integrated control module (the chart prints the first digit as BLANK), and also use the RECALL push button in Standby (no thermostat demand, press 2-5 seconds) to note the six most recent faults, so 06 is not lost when power is cycled.
- Safety: switch the thermostat off, open the outdoor disconnect and the breaker, verify 0 VAC line-to-line and line-to-ground at the contactor with a meter before touching wiring, and treat the run capacitor as charged - discharge it through a resistor and re-verify 0 V before handling it.
- Locate the part: the run capacitor and its wiring are in the outdoor unit's control box behind the control access panel (where the code is read); the compressor start winding is tested at the compressor terminals, under the compressor terminal cover in the base of the outdoor unit.
- Test: with power off, discharge the run capacitor and measure its microfarads against rating - a failed capacitor is the common, cheap cause and is replaced before condemning the compressor. With a good capacitor, ohm the compressor start winding at its terminals: an open (OL) start winding proves the compressor itself has failed, while finite winding resistance with an open in the connecting leads pinpoints the wiring. → Shop the run capacitor at Amazon
- End at the pinpoint: replace the Run capacitor or repair the wiring as condemned and retest; an open start winding pinpoints a failed compressor, which is sealed-system, EPA-certified technician work. The fault clears after 1 normal cycle or by cycling 24 VAC to the control.
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the Run capacitor.
Parts that commonly fix the 06 code
- Run capacitor$5–$35Shop at Amazon
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Working on a specific model? The official Goodman manual is on Goodman's support site — you'll need your model number.
Find your model number on the outdoor unit's rating plate. It's the key to the right manual pages and the right parts.