Goodman Heat pump ComfortBridge heat pump condensing units d3 Error Code

What the d3 code means

Read on the integrated control module's 7-segment LED display behind the outdoor unit's control access panel (first digit blank), this is the chart's 'Configuration Mis-Match' fault, with the symptom that the heat pump fails to operate. The manual states the shared data sent to the integrated control module does not match the hardware configuration. Corrective actions mirror the other data faults: verify the system type (communicating or legacy), verify the shared data is correct for the specific model and repopulate it if required, or wire the system as a legacy system; the error clears once correct data is loaded.

Likely causes

  1. Shared data does not match the control's hardware configuration
  2. Shared data for a different model/configuration loaded
  3. Wrong system type configured

How to fix it — step by step

  1. Record the code before cycling power: remove the outdoor unit's control-box access panel and read all three 7-segment LED digits on the integrated control module (the chart prints the first digit as BLANK), and also use the RECALL push button in Standby (no thermostat demand, press 2-5 seconds) to note the six most recent faults, so d3 is not lost when power is cycled.
  2. Safety: switch the thermostat off, open the outdoor disconnect and the breaker, verify 0 VAC line-to-line and line-to-ground at the contactor with a meter before touching wiring, and treat the run capacitor as charged - discharge it through a resistor and re-verify 0 V before handling it.
  3. Locate the part: the integrated control module in the outdoor unit's control box, behind the control access panel, is where the shared data lives; the BTSDL01 device used to load that data inserts into this control.
  4. Test: compare the configuration implied by the loaded shared data against the hardware actually installed (unit size and type on the rating plate) - a mismatch between the plate and the loaded data proves the data is wrong. Correct data that still will not match the hardware points to the control module itself.
  5. End at the fix: repopulate the correct shared data for this specific model/configuration with the BTSDL01 inserted before power-on, restore power and confirm d3 clears; if correct data cannot be made to match, replace the Control board. → Shop the control board at Amazon

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix the d3 code

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manufacturer documentation

Manual & model number

Working on a specific model? The official Goodman manual is on Goodman's support site — you'll need your model number.

Find your model number on the outdoor unit's rating plate. It's the key to the right manual pages and the right parts.

Related Goodman Heat pump ComfortBridge heat pump condensing units error codes

See all Goodman ComfortBridge heat pump condensing units codes & guides →