Goodman Heat pump ComfortBridge heat pump condensing units A3 Error Code

What the A3 code means

Read on the integrated control module's 7-segment LED display behind the outdoor unit's control access panel (first digit blank), this is the chart's 'Outdoor coil temp sensor fault,' and the manual's listed symptom is that the heat pump fails to operate in heating mode. Causes given are a shorted, open, disconnected or out-of-range sensor, with the corrective action to check the sensor connection and replace an open or shorted sensor. This sensor tells the control the outdoor coil temperature for defrost control, so its failure disables heating and defrost logic.

Likely causes

  1. Shorted outdoor coil temperature sensor
  2. Open outdoor coil temperature sensor
  3. Sensor disconnected from the control board
  4. Sensor out of range

How to fix it — step by step

  1. Record the code before cycling power: remove the outdoor unit's control-box access panel and read all three 7-segment LED digits on the integrated control module (the chart prints the first digit as BLANK), and also use the RECALL push button in Standby (no thermostat demand, press 2-5 seconds) to note the six most recent faults, so A3 is not lost when power is cycled.
  2. Safety: switch the thermostat off, open the outdoor disconnect and the breaker, verify 0 VAC line-to-line and line-to-ground at the contactor with a meter before touching wiring, and treat the run capacitor as charged - discharge it through a resistor and re-verify 0 V before handling it.
  3. Locate the part: the outdoor coil temperature sensor (defrost sensor/thermistor) is clipped to a feeder tube entering the outdoor coil, with its lead running to the integrated control module in the control box; access is through the control access panel, following the lead to the coil.
  4. Test: with power off, unplug the sensor and measure its resistance - OL proves an open sensor or lead and near-zero ohms proves a short; a reading wildly inconsistent with the actual coil temperature proves an out-of-range sensor. A sensor that tests correctly shifts suspicion to its harness and board input.
  5. End at the fix: replace the Defrost sensor if it tests open, shorted or out of range, or reseat/repair its connection, then restore power, run a heating call and confirm A3 stays clear and defrost can initiate; if it returns with a good sensor, replace the Control board. → Shop the control board at Amazon

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix the A3 code

Parts run $25–$80

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manufacturer documentation

Manual & model number

Working on a specific model? The official Goodman manual is on Goodman's support site — you'll need your model number.

Find your model number on the outdoor unit's rating plate. It's the key to the right manual pages and the right parts.

Related Goodman Heat pump ComfortBridge heat pump condensing units error codes

See all Goodman ComfortBridge heat pump condensing units codes & guides →