Goodman Heat pump ComfortBridge heat pump condensing units d1 Error Code

What the d1 code means

Read on the integrated control module's 7-segment LED display behind the outdoor unit's control access panel (first digit blank), this is the chart's 'Invalid Data on Network' fault, with the symptom that the heat pump fails to operate. The manual explains the unit is wired as part of a communicating system and the integrated control module contains invalid shared data, or network data is invalid for the module. Corrective actions are to verify the system type, populate correct shared data using the BTSDL01, or wire the system as a legacy system; the error clears once valid data is loaded.

Likely causes

  1. Invalid shared data loaded in the control module
  2. Network data invalid for the integrated control module
  3. Shared data for the wrong model populated into the control

How to fix it — step by step

  1. Record the code before cycling power: remove the outdoor unit's control-box access panel and read all three 7-segment LED digits on the integrated control module (the chart prints the first digit as BLANK), and also use the RECALL push button in Standby (no thermostat demand, press 2-5 seconds) to note the six most recent faults, so d1 is not lost when power is cycled.
  2. Safety: switch the thermostat off, open the outdoor disconnect and the breaker, verify 0 VAC line-to-line and line-to-ground at the contactor with a meter before touching wiring, and treat the run capacitor as charged - discharge it through a resistor and re-verify 0 V before handling it.
  3. Locate the part: the integrated control module is in the outdoor unit's control box behind the control access panel, and the BTSDL01 shared-data device inserts into it; check also the communicating wiring between outdoor unit, indoor unit and thermostat for damaged or mis-landed conductors.
  4. Test: verify the model data loaded matches this exact outdoor model - data for a different model is itself the failure. Inspect the communicating bus wiring for shorts or crossed connections; sound wiring plus wrong-model data pinpoints the data, while correct data plus d1 persisting points to the control module.
  5. End at the fix: repopulate the correct shared data for this specific model with the BTSDL01 inserted before power-on, or configure/wire the system as legacy if applicable, then restore power and confirm d1 clears; if correct data will not load or hold, replace the Control board. → Shop the control board at Amazon

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix the d1 code

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manufacturer documentation

Manual & model number

Working on a specific model? The official Goodman manual is on Goodman's support site — you'll need your model number.

Find your model number on the outdoor unit's rating plate. It's the key to the right manual pages and the right parts.