AO Smith Water heater Common Problems
Find your problem in the list below. Each page explains the most likely causes, step-by-step checks you can do yourself, when to call a pro, and the parts that commonly resolve it. 30 problems covered.
Not sure of the code? Tap along with it
If your AO Smith Water heater blinks or beeps a pattern instead of showing a code, tap the button in time with each blink or beep. A pause longer than a second and a half starts a new group - we will match the rhythm to a code.
Your taps: -
Finding your model number: it is on the unit's rating plate.
Tap any code for its full fix — causes, step-by-step checks, and the parts that commonly fix it.
All models
| Problem | What it means | Check first | |
|---|---|---|---|
| 0 flashes | The status light is dark: the pilot is not lit, or the thermopile has not yet reached normal operating… | Pilot light is out | › |
| 1 flash | Normal operation. The pilot is lit and the gas control valve has detected no problem; the status light… | Normal operation — no fault is present | › |
| 2 flashes | The pilot is lit but the thermopile is not producing the required output voltage, so the gas control is… | Defective or weakening thermopile | › |
| 4 flashes | The gas control valve's temperature sensor detected water temperature that was too high. The control shut off… | Gas control valve/thermostat failed to shut the burner off at setpoint | › |
| 5 flashes | The temperature sensor (thermistor) in the gas control valve is defective, so the control cannot trust its… | Defective temperature sensor (thermistor) in the gas control valve | › |
| 7 flashes | The gas control valve has failed internally. The control's self-diagnostics have shut the heater down and the… | Internal gas control valve failure | › |
| 8 flashes | The control still sees thermopile power after the knob was turned OFF. Either the thermopile is cooling more… | Thermopile cooling down more slowly than expected after shutoff | › |
| No hot water | The gas heater is producing no hot water at all. On this FVIR atmospheric line the status light tells you… | Pilot light out, so the burner never fires | › |
| Not enough hot water | The heater makes hot water but runs short or delivers it too cool. The causes are mostly outside the burner… | Faulty thermostatic mixing valve in a faucet or shower control | › |
| Pilot light won't stay lit | The pilot lights but goes out, or the status light never starts flashing, so the main burner never gets a… | Loose thermopile or thermal switch wiring connections | › |
| Rumbling or Popping Noises | Rumbling, popping or banging from a AO Smith tank while it heats is almost always sediment: minerals settle… | Sediment and mineral scale settled on the tank bottom, with water trapped beneath | › |
| Smelly Water | Rotten-egg or sulfur-smelling hot water from a AO Smith tank is hydrogen sulfide gas made inside the tank… | Sulfate-reducing bacteria in the tank reacting with sulfate in the supply water | › |
| Water Too Hot | Water that is too hot from a AO Smith tank is a scald hazard first and a fault second. Start with the setting… | Thermostat simply set too high — many tanks are factory-set near 140F, above the | › |
| Won't Turn On | An A. O. Smith heater that 'won't turn on' means two different machines. On an ELECTRIC tank, A. O. Smith's… | No power to the heater: tripped breaker or a house wiring fault — A. O. Smith's first | › |
Intelli-Vent power-vent models
| Problem | What it means | Check first | |
|---|---|---|---|
| 1 flash | The Intelli-Vent control has sensed an inadequate or missing earth ground and will not operate safely. | Wall outlet not properly grounded | › |
| 10 flashes | A flame signal has been sensed out of proper sequence — the control sees flame when none should be present. | Flame present out of sequence (lingering flame or flame sensor fault) | › |
| 11 flashes | Tank water temperature exceeded 195°F and activated the ECO (energy cut-off). The control has shut the heater… | Failed temperature control letting the burner overheat the tank | › |
| 12 flashes | Self-diagnostics detected one or both temperature adjust buttons are stuck, so temperature settings can no… | Stuck temperature adjust button on the control | › |
| 13 flashes | Self-diagnostics detected the water temperature sensor (thermistor) is either open or shorted, so the control… | Open or shorted temperature sensor (thermistor) | › |
| 14 flashes | Self-diagnostics detected the flammable vapor sensor is either open or shorted. The control locks out when… | Flammable vapor sensor failed open or shorted | › |
| 15 flashes | The control detected the presence of flammable vapors and is in a hard lockout that cycling power alone will… | Flammable vapors present near the heater (gasoline, paint, thinners, cleaners stored | › |
| 16 flashes | LDO (lint, dust, and oil) lockout. Contamination is choking combustion air, and the air pressure switch… | Lint, dust, or oil clogging the intake air screen on the base ring | › |
| 17 flashes | The air pressure switch circuit is opening repeatedly during one heating cycle. The pressure switch and the… | Failing air pressure switch | › |
| 2 flashes | The power supply to the Intelli-Vent control has reversed polarity — the 120 VAC hot and neutral are swapped. | Wall outlet wired with reversed polarity | › |
| 3 flashes | The pressure switch circuit remained closed for more than 5 seconds after the heating cycle began, and the… | Pressure switch contacts welded or failed closed | › |
| 4 flashes | The pressure switch circuit remained open longer than 5 seconds after the blower was energized, so the… | Blower not running or not receiving 120 VAC | › |
| 5 flashes | The Intelli-Vent control detected an open ignitor circuit — the hot surface ignitor is not drawing current. | Damaged or worn ignitor wiring | › |
| 6 flashes | Ignition/flame failure. The heater reached its maximum number of ignition retries and is locked out for one… | Gas supply turned off or supply/manifold pressure too low | › |
| 7 flashes | Self-diagnostics found a fault in the gas valve driver circuit, the internal microprocessor, or other… | Failed gas valve driver circuit | › |
ProLine XE Hybrid Electric Heat Pump
| Problem | What it means | Check first | |
|---|---|---|---|
| No hot water | This heat pump hybrid is producing no hot water. The most likely causes start with power and mode before… | No power to the water heater (no lights on the unit) | › |
Once you know the part you need, browse AO Smith Water heater replacement parts → The parts shelves are organized by brand, with the parts that actually fix these codes.