AO Smith Water heater 4 flashes
What it should look like on your machine
then it repeats
4 flashes - then the pattern repeats. Count along with your machine and compare.
What this problem usually means
The gas control valve's temperature sensor detected water temperature that was too high. The control shut off the main burner and the pilot; the code only displays immediately after the pilot is relit.
Likely causes
- Gas control valve/thermostat failed to shut the burner off at setpoint
- Temperature sensor in the gas control valve reading a genuine overheat condition
How to fix it — step by step
- Turn the gas control valve/thermostat knob to OFF. Locate the suspect part: the gas control valve/thermostat is the large control mounted on the front of the tank, low down, with the temperature knob on its face and its temperature sensor extending into the tank from its back. Access is external — the control is on the outside of the tank; replacing it means draining the tank and breaking gas connections (below).
- Relight the pilot and watch the status light: if 4 flashes are observed again, the overheat fault is confirmed — the sensor in the control has again read too-high temperature. Check actual hot-water temperature at a tap: genuinely scalding water confirms the control failed to shut the burner off at setpoint; normal tap temperature with a repeat code means the control's sensor is misreading. Both results condemn the gas control.
- Turn the gas control valve/thermostat knob to OFF and turn the main gas supply OFF.
- Replace the gas control valve/thermostat (A.O. Smith gas manual procedure, same threaded combination-control design): knob to OFF, gas off at the manual shut-off, drain the heater, disconnect the igniter wire and the red (+) and white (-) thermopile wires with needle-nose pliers, disconnect the pilot tube (7/16 in. wrench) and manifold tube (3/4 in. wrench; LP uses left-hand threads) at the control, disconnect the ground joint union and remaining gas pipe, then thread a 4 in. section of gas pipe into the inlet and use it — never a pipe wrench on the body — to turn the control counterclockwise out of the tank. Fit the new control in reverse with approved Teflon tape/pipe compound on the fitting that screws into the tank, do not overtighten, and remove the pilot ferrule nut from the new control. → Shop the gas control valve at Amazon
- Turn the main gas on and leak-test every gas connection with approved noncorrosive leak-detection solution (bubbles mean a leak — correct it), refill the tank completely before lighting, light the pilot and main burner per the label, and leak-test the manifold and pilot connections again with the burner lit.
- Tell the technician: 4 flashes confirmed on relight, and the actual tap temperature you measured versus the setpoint. What this job involves: gas-line disconnection, tank draining and a threaded-in control replacement with leak testing — licensed gas work in most jurisdictions.
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the gas control valve.
Parts that commonly fix it
- gas control valve$115–$500Shop at Amazon
- Tools for this job, if you need them$5–$25
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.