AO Smith Water heater Intelli-Vent power-vent models 17 flashes
What it should look like on your machine
then it repeats
17 flashes - then the pattern repeats. Count along with your machine and compare.
What this problem usually means
The air pressure switch circuit is opening repeatedly during one heating cycle. The pressure switch and the vent temperature limit switch are wired in series, so either switch opening produces this code.
Likely causes
- Failing air pressure switch
- Vent temperature limit switch opening during the cycle
- Weak blower or restricted venting dropping draft mid-cycle
How to fix it — step by step
- Locate the series pair: the air pressure switch is at the blower housing on top of the tank and the vent temperature limit switch is in the vent path at the blower outlet — they are wired in series, so either one opening mid-cycle produces this code, and they are tested separately.
- Test the air pressure switch performance with a digital manometer and a continuity check of its contacts, following technical bulletin TB-A023-06: a switch whose contacts bounce or drop out at steady draft is replaced (sensing tube and wires off, mounting screws out, rating matched exactly).
- Check the vent temperature limit switch with a meter across a full heating cycle and replace it if it opens at normal operating temperatures (unclipped from the vent housing, wires transferred). → Shop the vent temperature limit switch at Amazon
- Inspect the vent run for restriction and confirm the blower delivers steady draft for a full heating cycle; a blower losing speed mid-cycle is replaced as an assembly (power off, vent and wiring disconnected, lifted off the tank top).
- If you hand it over, tell the technician: 17 flashes — the series pressure/limit circuit is opening repeatedly during one cycle — and which switch your tests caught opening.
- Verify after the repair: restore gas, water and power, then open a hot tap and let the heater fire and run for several minutes - the heater should run clean through the whole draw. If it comes back, the repair did not cure it: hand over the point in the sequence where it reappears, because that timing is the diagnosis
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the pressure switch.
Shop the pressure switch at Amazon
Also tied to this fault: vent temperature limit switch - Shop at Amazon; blower assembly - Shop at Amazon
Parts that commonly fix it
- pressure switch$50–$205Shop at Amazon
- vent temperature limit switchShop at Amazon
- blower assemblyShop at Amazon
- Tools for this job, if you need them$15–$65
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.
Related AO Smith Water heater Intelli-Vent power-vent models problems
- 2 flashes
- 3 flashes
- 4 flashes
- 5 flashes
- 6 flashes
- 7 flashes
- 1 flash
- 10 flashes
- 11 flashes
- 12 flashes
- 13 flashes
- 14 flashes
See all AO Smith Intelli-Vent power-vent models codes & guides →