AO Smith Water heater Won't Turn On
What this problem usually means
An A. O. Smith heater that 'won't turn on' means two different machines. On an ELECTRIC tank, A. O. Smith's own manual lists the no-hot-water causes in this order: no power to the heater, a tripped energy cut-off (ECO — the red reset button on the upper thermostat), or a failed upper thermostat or upper element. The ECO is the centre of the electric branch: it cuts power to the elements if the tank overheats, it must be pressed by hand to reset, and the interpretation is precise — a click when you press it means it had tripped, and a tripped ECO usually means an element or thermostat fault caused the overheating, so the cause must be found before power is restored; no click means the ECO was never the problem and the upper thermostat is checked next. On a GAS tank, 'won't turn on' is a pilot problem: the electronic gas control runs on millivolt power the thermopile makes from the pilot flame, so a dark status light simply means the pilot is out or the thermopile is too weak — relight first, electronics second. The hybrid heat-pump models add a display branch: no lights on the unit at all is listed by A. O. Smith as 'no power to the water heater' — breaker and fuse first.
Likely causes
- No power to the heater: tripped breaker or a house wiring fault — A. O. Smith's first listed cause for an electric tank
- Tripped energy cut-off (ECO): the red reset on the upper thermostat opened after an overheat; a click on reset confirms it, and it points back at a faulty element or thermostat
- Failed upper thermostat or burned-out upper element (electric): no hot water at all; a failed lower element instead gives a short burst of hot water, then cold
- Gas models: pilot out, so the thermopile makes no millivolt power and the gas control's status light stays dark
- Weak pilot flame (clogged orifice, poor draft), failed thermopile, or a loose thermopile connector at the gas control
- Hybrid models: Vacation mode engaged, or the high-temperature limit switch open — both listed by A. O. Smith for a unit that appears off
How to fix it — step by step
- Prove the house supply first: find the water heater's double-pole breaker. A tripped breaker sits mid-way — switch it fully OFF, then ON. If it trips again right away, leave it off and stop: a shorted element is the usual reason, and that fact goes to the technician. For a gas model, also confirm the gas shutoff valve on the line to the heater is open
- Branch by fuel. ELECTRIC (including hybrid): go to step 3. GAS with a status light on the gas control: go to step 5. Hybrid with a display: if the display is lit, check the mode first — A. O. Smith lists Vacation mode as a cause of a unit that seems off; press Mode/Enter and return to a heating mode before opening any panel
- Electric ECO check — the procedure, with the breaker OFF for all of it: remove the upper access panel on the front of the tank, fold back the insulation (do not remove the plastic safety cover over the thermostat), and press the red ECO reset button on the upper thermostat firmly. Then replace the insulation and panel before turning the breaker back on → Shop the upper thermostat at Amazon
- Read the ECO result this way: a CLICK means the ECO had tripped, the tank overheated, and in most cases that means a problem with an element or thermostat, which a qualified person should check; do not restore power until the cause of the overheating has been identified and repaired, so one reset to confirm the diagnosis is the owner step, and a second trip ends owner work. NO CLICK means the ECO was not tripped — the fault is downstream: the upper thermostat is checked next, then the upper element (both behind that same upper panel, the element screwed into the tank behind the thermostat). Power proven + ECO untripped + no heat = upper thermostat/upper element is the pinpoint for the technician
- Gas branch — relight by the label: turn the gas control knob to OFF and wait 10 minutes (A. O. Smith's stated wait), then follow the lighting instructions printed on the tank: knob to PILOT, hold it in, click the igniter about once a second for up to 90 seconds, and watch for the pilot flame. Keep the pilot running up to 90 seconds for the thermopile to reach temperature before expecting the status light to blink — a blinking light means the control now has power; turn the knob to your temperature setting and confirm the main burner fires
- Gas branch — pilot lights but the light never blinks, or the pilot won't stay lit: remove the outer burner door and press the reset button on the thermal switch if your model has one, replace the door, wait 10 minutes and relight (A. O. Smith's sequence). Then judge the flame through the viewport: strong, blue and enveloping the thermopile tip = flame is fine, so a still-dark light after 90 seconds means the pilot is too weak electrically — the thermopile is defective or a wiring connector is loose (A. O. Smith's own three-way split). Weak or wandering flame = clogged pilot orifice or poor draft. One safety stop from the manual: blue or black discoloration on the flame arrestor (visible at the base) means a flammable-vapour incident — do not use the heater; it requires inspection and the heater will require replacement → Shop the thermopile at Amazon
- Verify over a full recovery: status light blinking normally (gas) or the tank recovering (electric), the main burner firing on a temperature call, and hot water at a tap. Note what you found — breaker, ECO click or no click, pilot behaviour — because each result names a different part, and that note is the technician's shortcut if the fault returns
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the energy cut-off (ECO) / high-limit control.
Shop the energy cut-off (ECO) / high-limit control at Amazon
Also tied to this fault: upper thermostat - Shop at Amazon; upper heating element - Shop at Amazon; thermopile - Shop at Amazon; pilot assembly - Shop at Amazon; gas control valve - Shop at Amazon
Parts that commonly fix it
- energy cut-off (ECO) / high-limit controlShop at Amazon
- upper thermostat$10–$20Shop at Amazon
- upper heating element$10–$50Shop at Amazon
- thermopile$25–$80Shop at Amazon
- pilot assembly$30–$120Shop at Amazon
- gas control valve$115–$500Shop at Amazon
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.