What this problem usually means

The control detected the presence of flammable vapors and is in a hard lockout that cycling power alone will not reset. The lockout triggers when flammable vapor sensor resistance is above 70,000 ohms but below 1,700,000 ohms.

Likely causes

  1. Flammable vapors present near the heater (gasoline, paint, thinners, cleaners stored nearby)
  2. Failed flammable vapor sensor reading high with no vapors present

How to fix it — step by step

  1. Turn power off and remove anything that can emit flammable vapors from the area around the heater; store it in a different location.
  2. Remove the sensor from its base-ring bracket, disconnect both wires, and measure its resistance by the heater, then again outdoors after 5 minutes of acclimation, on a scale above 70,000 ohms.
  3. If resistance is high indoors only and drops below 70,000 ohms outdoors, vapors remain in the area — find and remove the source and repeat the test.
  4. If resistance stays above 70,000 ohms indoors and outdoors, replace the flammable vapor sensor.
  5. If resistance is below 70,000 ohms in both tests and the steps above are complete, replace the Intelli-Vent control.
  6. After the hazard is removed, a qualified person performs the manual reset: power off 10 seconds, restore power, then within 10 seconds press both temperature adjust buttons together until the green Vacation LED blinks (about 5 seconds), release, and repeat until the Vacation LED is steady to clear the lockout.
  7. Verify the fix: restore gas, water and power, then open a hot tap and let the heater fire and run for several minutes - the heater should run clean through the whole draw. If it comes back, the fault is still present: recheck the step above whose result was borderline, and treat the part that step points to as the one to replace

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix it

Typical pro repair $228–$1,017
  • flammable vapor sensorShop at Amazon
  • Intelli-Vent gas control valve$115–$500Shop at Amazon
  • Tools for this job, if you need them$15–$65

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manual & model number

Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.

Related AO Smith Water heater Intelli-Vent power-vent models problems

See all AO Smith Intelli-Vent power-vent models codes & guides →