AO Smith Water heater Intelli-Vent power-vent models 16 flashes
What it should look like on your machine
then it repeats
16 flashes - then the pattern repeats. Count along with your machine and compare.
What this problem usually means
LDO (lint, dust, and oil) lockout. Contamination is choking combustion air, and the air pressure switch circuit is opening repeatedly during a single heating cycle.
Likely causes
- Lint, dust, or oil clogging the intake air screen on the base ring
- Clogged dilution air screen on the blower assembly
- Clogged flame arrestor
- Damaged or misinstalled flue baffle
- Over-firing (wrong burner orifice or high manifold pressure)
- Vent temperature limit switch opening at normal temperatures
How to fix it — step by step
- Check and clean the intake air screen on the base ring of the water heater.
- Check and clean the dilution air screen on the blower assembly.
- Clean the flame arrestor through the base-ring intake opening with a non-metallic brush, then vacuum the arrestor and base ring chamber thoroughly.
- Remove the blower assembly and inspect the flue baffle; reinstall it correctly or replace it if worn or damaged. → Shop the flue baffle at Amazon
- Check the burner orifice size and replace it if the wrong orifice is installed; check manifold pressure — it is non-adjustable, so replace the Intelli-Vent control if it is off by more than 0.3 in. W.C. → Shop the burner orifice at Amazon
- Replace the vent temperature limit switch if it opens its contacts at normal operating temperatures. → Shop the vent temperature limit switch at Amazon
- Verify after the repair: restore gas, water and power, then open a hot tap and let the heater fire and run for several minutes - the heater should run clean through the whole draw. If it comes back, the repair did not cure it: hand over the point in the sequence where it reappears, because that timing is the diagnosis
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the flue baffle.
Shop the flue baffle at Amazon
Also tied to this fault: burner orifice - Shop at Amazon; vent temperature limit switch - Shop at Amazon
Parts that commonly fix it
- flue baffleShop at Amazon
- burner orificeShop at Amazon
- vent temperature limit switchShop at Amazon
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.
Related AO Smith Water heater Intelli-Vent power-vent models problems
- 17 flashes
- 2 flashes
- 3 flashes
- 4 flashes
- 5 flashes
- 6 flashes
- 7 flashes
- 1 flash
- 10 flashes
- 11 flashes
- 12 flashes
- 13 flashes
See all AO Smith Intelli-Vent power-vent models codes & guides →