AO Smith Water heater Intelli-Vent power-vent models 2 flashes
What it should look like on your machine
then it repeats
2 flashes - then the pattern repeats. Count along with your machine and compare.
What this problem usually means
The power supply to the Intelli-Vent control has reversed polarity — the 120 VAC hot and neutral are swapped.
Likely causes
- Wall outlet wired with reversed polarity
- Reversed wires in the internal 120 VAC wiring connections or wiring harness
How to fix it — step by step
- Verify the wall outlet is properly wired with a plug-in outlet tester: a reversed-polarity indication means the outlet's hot and neutral are swapped - the fault is in the outlet wiring and the control is correctly refusing to run. An outlet that tests correct rules the supply out; the reversed wires are then inside the heater, which is the next check.
- Check all internal 120 VAC wiring connections and the wiring harness for reversed wires; the 120 VAC hot wire must connect to the on/off switch.
- Verify the fix: restore gas, water and power, then open a hot tap and let the heater fire and run for several minutes - the heater should run clean through the whole draw. If it comes back, the fault is still present: recheck the step above whose result was borderline, and treat the part that step points to as the one to replace
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
Then the fault is internal - there is no documented owner fix beyond the steps above. If you're not comfortable taking it apart yourself, a repair shop is the next step.
Parts that commonly fix it
No specific replacement part is documented for this fault. If the checks above do not clear it, your water heater likely needs to be disassembled and an internal part replaced - and since the manufacturer publishes no procedure for that, it is the point where most owners hand it to a repair shop.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.
Related AO Smith Water heater Intelli-Vent power-vent models problems
- 3 flashes
- 4 flashes
- 5 flashes
- 6 flashes
- 7 flashes
- 1 flash
- 10 flashes
- 11 flashes
- 12 flashes
- 13 flashes
- 14 flashes
- 15 flashes
See all AO Smith Intelli-Vent power-vent models codes & guides →