AO Smith Water heater Intelli-Vent power-vent models 10 flashes

What it should look like on your machine

then it repeats

10 flashes - then the pattern repeats. Count along with your machine and compare.

What this problem usually means

A flame signal has been sensed out of proper sequence — the control sees flame when none should be present.

Likely causes

  1. Flame present out of sequence (lingering flame or flame sensor fault)
  2. Internal control fault

How to fix it — step by step

  1. Turn power off for 10–20 seconds, then back on to clear the code.
  2. If the code persists, split the two causes before replacing anything: the flame sensor is the rod in the burner flame under the tank behind the access door. Inspect it and its lead for a short to ground or a rod bent into a false position — a sensor fault is repaired by cleaning, repositioning or replacing the sensor (one screw, one wire). A genuinely lingering flame with the control off is a gas-side fault and the heater stays off.
  3. Only if the sensor and its wiring are sound does the code condemn the Intelli-Vent control itself, which is replaced following the gas control replacement procedure, with all gas connections leak-tested and a full cycle to prove it.
  4. If you hand it over, tell the technician: 10 flashes — flame sensed out of sequence — persisting after a reset.
  5. Verify after the repair: restore gas, water and power, then open a hot tap and let the heater fire and run for several minutes - the heater should run clean through the whole draw. If it comes back, the repair did not cure it: hand over the point in the sequence where it reappears, because that timing is the diagnosis

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix it

Typical pro repair $228–$1,017

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.