AO Smith Water heater Intelli-Vent power-vent models 10 flashes
What it should look like on your machine
then it repeats
10 flashes - then the pattern repeats. Count along with your machine and compare.
What this problem usually means
A flame signal has been sensed out of proper sequence — the control sees flame when none should be present.
Likely causes
- Flame present out of sequence (lingering flame or flame sensor fault)
- Internal control fault
How to fix it — step by step
- Turn power off for 10–20 seconds, then back on to clear the code.
- If the code persists, split the two causes before replacing anything: the flame sensor is the rod in the burner flame under the tank behind the access door. Inspect it and its lead for a short to ground or a rod bent into a false position — a sensor fault is repaired by cleaning, repositioning or replacing the sensor (one screw, one wire). A genuinely lingering flame with the control off is a gas-side fault and the heater stays off.
- Only if the sensor and its wiring are sound does the code condemn the Intelli-Vent control itself, which is replaced following the gas control replacement procedure, with all gas connections leak-tested and a full cycle to prove it.
- If you hand it over, tell the technician: 10 flashes — flame sensed out of sequence — persisting after a reset.
- Verify after the repair: restore gas, water and power, then open a hot tap and let the heater fire and run for several minutes - the heater should run clean through the whole draw. If it comes back, the repair did not cure it: hand over the point in the sequence where it reappears, because that timing is the diagnosis
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the Intelli-Vent gas control valve.
Parts that commonly fix it
- Intelli-Vent gas control valve$115–$500Shop at Amazon
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.
Related AO Smith Water heater Intelli-Vent power-vent models problems
- 11 flashes
- 12 flashes
- 13 flashes
- 14 flashes
- 15 flashes
- 16 flashes
- 17 flashes
- 2 flashes
- 3 flashes
- 4 flashes
- 5 flashes
- 6 flashes
See all AO Smith Intelli-Vent power-vent models codes & guides →