AO Smith Water heater Intelli-Vent power-vent models 11 flashes

What it should look like on your machine

then it repeats

11 flashes - then the pattern repeats. Count along with your machine and compare.

What this problem usually means

Tank water temperature exceeded 195°F and activated the ECO (energy cut-off). The control has shut the heater down on high limit.

Likely causes

  1. Failed temperature control letting the burner overheat the tank
  2. Defective ECO/temperature sensor in the control

How to fix it — step by step

  1. Do not keep resetting an overheating heater without finding why it overheated — tank water exceeded 195°F and the ECO (energy cut-off) in the control shut it down.
  2. Locate the suspect part: the Intelli-Vent gas control valve is the electronic gas control mounted on the front of the tank, low down; the ECO/temperature sensor is inside that control, sensing tank temperature through its probe into the tank. Access is external — the control is on the outside of the tank; there is no separate ECO part to reach inside the tank.
  3. Turn power off for 10–20 seconds, then back on to clear the code, and verify actual water temperature at a tap: genuinely over-hot water means the control let the burner overheat the tank (failed temperature control); normal temperature with an immediate repeat 11-flash trip means the ECO/sensor inside the control is defective. Either way the pinpoint is the Intelli-Vent control — but a genuine overheat also requires checking for a stuck/recirculating cause before the new control is trusted.
  4. Replace the Intelli-Vent control if the code persists: it is replaced as a gas control — gas off, drain the heater, disconnect its wiring, pilot and manifold connections and gas piping, unthread the old control from the tank (pipe threaded into the inlet as the turning lever, never a wrench on the body), fit the new control with approved tape/compound, reconnect, leak-test all gas joints with approved solution, and refill the tank completely before lighting.
  5. Tell the technician: 11 flashes ECO trip over 195°F, and whether the tap water was actually over-hot or normal temperature. What this job involves: gas-line disconnection, tank draining and control replacement with leak testing — licensed gas work in most jurisdictions.
  6. Verify after the repair: restore gas, water and power, then open a hot tap and let the heater fire and run for several minutes - the heater should run clean through the whole draw. If it comes back, the repair did not cure it: hand over the point in the sequence where it reappears, because that timing is the diagnosis

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix it

Typical pro repair $228–$1,017
  • Intelli-Vent gas control valve$115–$500Shop at Amazon
  • Tools for this job, if you need them$10–$20

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.