What this problem usually means
The Intelli-Vent control detected an open ignitor circuit — the hot surface ignitor is not drawing current.
Likely causes
- Damaged or worn ignitor wiring
- Poor connection at the ignitor plug or the socket on the control body
- Worn-out hot surface ignitor (resistance risen out of range)
How to fix it — step by step
- Locate the suspect part: the hot surface ignitor assembly is in the burner compartment at the base of the tank, reached through the lower burner/manifold door area, and its plug connects to the socket on the body of the Intelli-Vent control — the electronic gas control mounted on the front of the tank. Access: power off, then the ignitor wiring and plug can be checked at the control body externally; the ignitor itself is inspected through the burner door.
- Inspect the wiring to the hot surface ignitor and replace the ignitor assembly if the wiring is damaged or worn — damaged wiring opens the circuit exactly like a failed ignitor.
- Check the ignitor assembly plug and the socket on the Intelli-Vent body for a solid connection — a loose plug is an open circuit; reseat it and retest before condemning parts.
- Measure ignitor resistance at the plug end at room temperature (77°F): replace the ignitor if it is not within 11.5–18.8 ohms; resistance near 18.8 ohms means the ignitor is near end of life. In-range resistance with a firm plug and undamaged wiring rules the ignitor out.
- To replace the ignitor: power and gas off, unplug it at the control body, remove it from its burner-compartment mounting, fit the new assembly without touching the element with bare hands, reconnect the plug, restore power and prove an ignition cycle.
- If wiring, connection, and resistance all test good and the code persists, replace the Intelli-Vent control — the control body on the tank front, replaced as a gas control (drain, disconnect, unthread, refit, leak-test, refill before lighting).
- Tell the technician: 5 flashes open ignitor circuit, the resistance you measured at the plug, and the plug/wiring condition. What this job involves: burner-compartment and gas-control work on a gas appliance.
- Verify after the repair: restore gas, water and power, then open a hot tap and let the heater fire and run for several minutes - the heater should run clean through the whole draw. If it comes back, the repair did not cure it: hand over the point in the sequence where it reappears, because that timing is the diagnosis
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the hot surface ignitor.
Parts that commonly fix it
- hot surface ignitorShop at Amazon
- Tools for this job, if you need them$15–$65
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.
Related AO Smith Water heater Intelli-Vent power-vent models problems
- 6 flashes
- 7 flashes
- 1 flash
- 10 flashes
- 11 flashes
- 12 flashes
- 13 flashes
- 14 flashes
- 15 flashes
- 16 flashes
- 17 flashes
- 2 flashes
See all AO Smith Intelli-Vent power-vent models codes & guides →