AO Smith Water heater Intelli-Vent power-vent models 3 flashes
What it should look like on your machine
then it repeats
3 flashes - then the pattern repeats. Count along with your machine and compare.
What this problem usually means
The pressure switch circuit remained closed for more than 5 seconds after the heating cycle began, and the blower does not start.
Likely causes
- Pressure switch contacts welded or failed closed
- Incorrect pressure switch circuit wiring, or a jumpered pressure switch
- Failed Intelli-Vent control
How to fix it — step by step
- Locate the circuit: the pressure switch is mounted at the blower housing on top of the tank, wired in series with the Intelli-Vent control at the front of the tank, with a sensing tube down to the vent connection.
- Check the pressure switch circuit wiring is correct and the switch is not jumpered — a jumpered switch produces exactly this code and is a safety defeat that must be corrected, not cleared.
- With power secured and wires disconnected, check continuity of the pressure switch contacts: contacts showing continuity (closed circuit) with no call and no draft mean the switch has failed — replace the pressure switch (wires and sensing tube off, mounting screws out, new switch matched to the same pressure rating, tube and wires refitted). → Shop the pressure switch at Amazon
- If the contacts are open and wiring is correct, turn power off for 10–20 seconds and back on to clear the code; if it persists, the Intelli-Vent control itself has failed and is replaced following the gas control removal and replacement procedure, with all gas connections leak-tested and a full firing cycle to prove it.
- If you hand it over, tell the technician: 3 flashes — pressure switch circuit closed more than 5 seconds into the cycle — and whether the switch contacts tested closed at rest.
- Verify after the repair: restore gas, water and power, then open a hot tap and let the heater fire and run for several minutes - the heater should run clean through the whole draw. If it comes back, the repair did not cure it: hand over the point in the sequence where it reappears, because that timing is the diagnosis
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the pressure switch.
Shop the pressure switch at Amazon
Also tied to this fault: Intelli-Vent gas control valve - Shop at Amazon
Parts that commonly fix it
- pressure switch$50–$205Shop at Amazon
- Intelli-Vent gas control valve$115–$500Shop at Amazon
- Tools for this job, if you need them$15–$65
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.
Related AO Smith Water heater Intelli-Vent power-vent models problems
- 4 flashes
- 5 flashes
- 6 flashes
- 7 flashes
- 1 flash
- 10 flashes
- 11 flashes
- 12 flashes
- 13 flashes
- 14 flashes
- 15 flashes
- 16 flashes
See all AO Smith Intelli-Vent power-vent models codes & guides →