AO Smith Water heater Intelli-Vent power-vent models 12 flashes

What it should look like on your machine

then it repeats

12 flashes - then the pattern repeats. Count along with your machine and compare.

What this problem usually means

Self-diagnostics detected one or both temperature adjust buttons are stuck, so temperature settings can no longer be adjusted reliably.

Likely causes

  1. Stuck temperature adjust button on the control

How to fix it — step by step

  1. Press and release the temperature adjust buttons on the Intelli-Vent control (the gas control at the front of the tank) several times to free a stuck button — a button held down by debris or a warped bezel is the whole fault on many of these.
  2. If the code clears, confirm both buttons now change the setpoint normally and the heater runs a normal cycle.
  3. If the code does not clear, the control keeps regulating at the last setting but settings are no longer adjustable — replace the Intelli-Vent control following the gas control replacement procedure, leak-testing all gas connections and proving a full cycle with the new buttons adjusting normally.
  4. If you hand it over, tell the technician: 12 flashes — temperature adjust button stuck on the Intelli-Vent control.
  5. Verify after the repair: restore gas, water and power, then open a hot tap and let the heater fire and run for several minutes - the heater should run clean through the whole draw. If it comes back, the repair did not cure it: hand over the point in the sequence where it reappears, because that timing is the diagnosis

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix it

Typical pro repair $228–$1,017

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.