AO Smith Water heater Pilot light won't stay lit
What this problem usually means
The pilot lights but goes out, or the status light never starts flashing, so the main burner never gets a chance to fire. Heat from the pilot must drive the thermopile; anything that weakens the flame or breaks that millivolt circuit drops the pilot.
Likely causes
- Loose thermopile or thermal switch wiring connections
- Tripped resettable thermal switch
- Weak pilot flame not heating the thermopile sufficiently
- Defective thermopile
How to fix it — step by step
- Remove the outer door, press the reset button in the center of the thermal switch, and check that the thermopile and thermal switch wiring connections at the gas control valve/thermostat are tight.
- Check the flame arrestor for blue or black discoloration; if it is discolored, do not relight — a flammable vapor incident is suspected and the heater needs a qualified technician's inspection.
- Replace the outer door, wait 10 minutes, and relight per the label: knob at PILOT held in while clicking the igniter about once per second for up to 90 seconds, holding the knob in until the status light starts blinking.
- If the pilot is visibly lit for a full 90 seconds and the status light still never blinks, the flame is not heating the thermopile enough or the thermopile has failed — replace the pilot/thermopile assembly. → Shop the pilot/thermopile assembly at Amazon
- Verify after the repair: restore gas, water and power, then open a hot tap and let the heater fire and run for several minutes - the heater should run clean through the whole draw. If it comes back, the repair did not cure it: hand over the point in the sequence where it reappears, because that timing is the diagnosis
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the pilot/thermopile assembly.
Shop the pilot/thermopile assembly at Amazon
Also tied to this fault: thermal switch - Shop at Amazon
Parts that commonly fix it
- pilot/thermopile assembly$25–$80Shop at Amazon
- thermal switchShop at Amazon
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.