AO Smith Water heater Intelli-Vent power-vent models 4 flashes

What it should look like on your machine

then it repeats

4 flashes - then the pattern repeats. Count along with your machine and compare.

What this problem usually means

The pressure switch circuit remained open longer than 5 seconds after the blower was energized, so the control cannot prove venting draft. The blower may run continuously in this condition.

Likely causes

  1. Blower not running or not receiving 120 VAC
  2. Pressure switch sensing tube disconnected, kinked, or damaged
  3. Vent temperature limit switch contacts open
  4. Wrong vent pipe size or length, excess elbows, or an obstructed vent pipe
  5. Defective pressure switch or blower

How to fix it — step by step

  1. Locate the proving chain: the blower is the fan assembly on top of the tank; the pressure switch is mounted at the blower housing with a sensing tube to the vent; the vent temperature limit switch is in the vent path at the blower outlet; the Intelli-Vent control is the gas control at the front of the tank.
  2. Confirm the blower runs and check for 120 VAC to the blower when the heating cycle begins; if the control never energises the blower, replace the Intelli-Vent control, and if the blower will not start when energised, replace the blower assembly (power off, vent and wiring disconnected, assembly lifted off the top of the tank). → Shop the blower assembly at Amazon
  3. Reconnect or replace the pressure switch sensing tube if it is kinked or damaged — a tube fault fakes every other part in this chain.
  4. Check continuity of the vent temperature limit switch and replace it if its contacts remain open under 160°F (switch unclipped from the vent housing, wires transferred). → Shop the vent temperature limit switch at Amazon
  5. Confirm the vent pipe size (2, 3, or 4 inch) matches the installation manual for the vent length, that elbow and equivalent-length limits are not exceeded, and clear any vent obstruction.
  6. Test the pressure switch with a digital manometer and continuity check: vacuum above the switch's setpoint with contacts still open condemns the switch, which is replaced (tube and wires off, mounting screws out, rating matched). If the switch tests good and the code persists, replace the Intelli-Vent control following the gas control replacement procedure, leak-testing all gas connections.
  7. If you hand it over, tell the technician: 4 flashes — pressure switch circuit open with the blower energised — and which of blower, tube, limit switch and switch you have already cleared.
  8. Verify after the repair: restore gas, water and power, then open a hot tap and let the heater fire and run for several minutes - the heater should run clean through the whole draw. If it comes back, the repair did not cure it: hand over the point in the sequence where it reappears, because that timing is the diagnosis

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix it

Typical pro repair $228–$1,017

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manual & model number

Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.

Related AO Smith Water heater Intelli-Vent power-vent models problems

See all AO Smith Intelli-Vent power-vent models codes & guides →