AO Smith Intelli-Vent power-vent models Common Problems

Find your problem in the list below. Each page explains the most likely causes, step-by-step checks you can do yourself, when to call a pro, and the parts that commonly resolve it. 15 problems covered.

Not sure of the code? Tap along with it

If your AO Smith Water heater blinks or beeps a pattern instead of showing a code, tap the button in time with each blink or beep. A pause longer than a second and a half starts a new group - we will match the rhythm to a code.

Your taps: -

Tap any code for its full fix — causes, step-by-step checks, and the parts that commonly fix it.

ProblemWhat it meansCheck first
1 flashThe Intelli-Vent control has sensed an inadequate or missing earth ground and will not operate safely.Wall outlet not properly grounded›
10 flashesA flame signal has been sensed out of proper sequence — the control sees flame when none should be present.Flame present out of sequence (lingering flame or flame sensor fault)›
11 flashesTank water temperature exceeded 195°F and activated the ECO (energy cut-off). The control has shut the heater…Failed temperature control letting the burner overheat the tank›
12 flashesSelf-diagnostics detected one or both temperature adjust buttons are stuck, so temperature settings can no…Stuck temperature adjust button on the control›
13 flashesSelf-diagnostics detected the water temperature sensor (thermistor) is either open or shorted, so the control…Open or shorted temperature sensor (thermistor)›
14 flashesSelf-diagnostics detected the flammable vapor sensor is either open or shorted. The control locks out when…Flammable vapor sensor failed open or shorted›
15 flashesThe control detected the presence of flammable vapors and is in a hard lockout that cycling power alone will…Flammable vapors present near the heater (gasoline, paint, thinners, cleaners stored›
16 flashesLDO (lint, dust, and oil) lockout. Contamination is choking combustion air, and the air pressure switch…Lint, dust, or oil clogging the intake air screen on the base ring›
17 flashesThe air pressure switch circuit is opening repeatedly during one heating cycle. The pressure switch and the…Failing air pressure switch›
2 flashesThe power supply to the Intelli-Vent control has reversed polarity — the 120 VAC hot and neutral are swapped.Wall outlet wired with reversed polarity›
3 flashesThe pressure switch circuit remained closed for more than 5 seconds after the heating cycle began, and the…Pressure switch contacts welded or failed closed›
4 flashesThe pressure switch circuit remained open longer than 5 seconds after the blower was energized, so the…Blower not running or not receiving 120 VAC›
5 flashesThe Intelli-Vent control detected an open ignitor circuit — the hot surface ignitor is not drawing current.Damaged or worn ignitor wiring›
6 flashesIgnition/flame failure. The heater reached its maximum number of ignition retries and is locked out for one…Gas supply turned off or supply/manifold pressure too low›
7 flashesSelf-diagnostics found a fault in the gas valve driver circuit, the internal microprocessor, or other…Failed gas valve driver circuit›

All AO Smith water heater models & codes →

Looking for a part?

Once you know the part you need, browse AO Smith Intelli-Vent power-vent models replacement parts → The parts shelves are organized by brand, with the parts that actually fix these codes.