AO Smith Intelli-Vent power-vent models Common Problems
Find your problem in the list below. Each page explains the most likely causes, step-by-step checks you can do yourself, when to call a pro, and the parts that commonly resolve it. 15 problems covered.
Not sure of the code? Tap along with it
If your AO Smith Water heater blinks or beeps a pattern instead of showing a code, tap the button in time with each blink or beep. A pause longer than a second and a half starts a new group - we will match the rhythm to a code.
Your taps: -
Tap any code for its full fix — causes, step-by-step checks, and the parts that commonly fix it.
| Problem | What it means | Check first | |
|---|---|---|---|
| 1 flash | The Intelli-Vent control has sensed an inadequate or missing earth ground and will not operate safely. | Wall outlet not properly grounded | › |
| 10 flashes | A flame signal has been sensed out of proper sequence — the control sees flame when none should be present. | Flame present out of sequence (lingering flame or flame sensor fault) | › |
| 11 flashes | Tank water temperature exceeded 195°F and activated the ECO (energy cut-off). The control has shut the heater… | Failed temperature control letting the burner overheat the tank | › |
| 12 flashes | Self-diagnostics detected one or both temperature adjust buttons are stuck, so temperature settings can no… | Stuck temperature adjust button on the control | › |
| 13 flashes | Self-diagnostics detected the water temperature sensor (thermistor) is either open or shorted, so the control… | Open or shorted temperature sensor (thermistor) | › |
| 14 flashes | Self-diagnostics detected the flammable vapor sensor is either open or shorted. The control locks out when… | Flammable vapor sensor failed open or shorted | › |
| 15 flashes | The control detected the presence of flammable vapors and is in a hard lockout that cycling power alone will… | Flammable vapors present near the heater (gasoline, paint, thinners, cleaners stored | › |
| 16 flashes | LDO (lint, dust, and oil) lockout. Contamination is choking combustion air, and the air pressure switch… | Lint, dust, or oil clogging the intake air screen on the base ring | › |
| 17 flashes | The air pressure switch circuit is opening repeatedly during one heating cycle. The pressure switch and the… | Failing air pressure switch | › |
| 2 flashes | The power supply to the Intelli-Vent control has reversed polarity — the 120 VAC hot and neutral are swapped. | Wall outlet wired with reversed polarity | › |
| 3 flashes | The pressure switch circuit remained closed for more than 5 seconds after the heating cycle began, and the… | Pressure switch contacts welded or failed closed | › |
| 4 flashes | The pressure switch circuit remained open longer than 5 seconds after the blower was energized, so the… | Blower not running or not receiving 120 VAC | › |
| 5 flashes | The Intelli-Vent control detected an open ignitor circuit — the hot surface ignitor is not drawing current. | Damaged or worn ignitor wiring | › |
| 6 flashes | Ignition/flame failure. The heater reached its maximum number of ignition retries and is locked out for one… | Gas supply turned off or supply/manifold pressure too low | › |
| 7 flashes | Self-diagnostics found a fault in the gas valve driver circuit, the internal microprocessor, or other… | Failed gas valve driver circuit | › |
All AO Smith water heater models & codes →
Once you know the part you need, browse AO Smith Intelli-Vent power-vent models replacement parts → The parts shelves are organized by brand, with the parts that actually fix these codes.