AO Smith Water heater Intelli-Vent power-vent models 13 flashes
What it should look like on your machine
then it repeats
13 flashes - then the pattern repeats. Count along with your machine and compare.
What this problem usually means
Self-diagnostics detected the water temperature sensor (thermistor) is either open or shorted, so the control has no valid temperature input.
Likely causes
- Open or shorted temperature sensor (thermistor)
- Damaged sensor wiring
How to fix it — step by step
- Turn power off for 10–20 seconds, then back on to clear the code.
- The sensor in question is the water temperature thermistor, wired to the Intelli-Vent control at the front of the tank. Before condemning the control, inspect the sensor's wiring run for a chafed, pinched or corroded connection — an open or short in the wire reads exactly like a failed sensor — and reseat its connector at the control.
- If the wiring is sound and the code persists, the thermistor is part of the control assembly on these models and the Intelli-Vent control is replaced following the gas control replacement procedure, with all gas connections leak-tested and a full cycle to prove it.
- If you hand it over, tell the technician: 13 flashes — water temperature sensor open or shorted — with the sensor wiring already inspected.
- Verify after the repair: restore gas, water and power, then open a hot tap and let the heater fire and run for several minutes - the heater should run clean through the whole draw. If it comes back, the repair did not cure it: hand over the point in the sequence where it reappears, because that timing is the diagnosis
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the Intelli-Vent gas control valve.
Parts that commonly fix it
- Intelli-Vent gas control valve$115–$500Shop at Amazon
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.
Related AO Smith Water heater Intelli-Vent power-vent models problems
- 14 flashes
- 15 flashes
- 16 flashes
- 17 flashes
- 2 flashes
- 3 flashes
- 4 flashes
- 5 flashes
- 6 flashes
- 7 flashes
- 1 flash
- 10 flashes
See all AO Smith Intelli-Vent power-vent models codes & guides →