AO Smith Water heater Intelli-Vent power-vent models 13 flashes

What it should look like on your machine

then it repeats

13 flashes - then the pattern repeats. Count along with your machine and compare.

What this problem usually means

Self-diagnostics detected the water temperature sensor (thermistor) is either open or shorted, so the control has no valid temperature input.

Likely causes

  1. Open or shorted temperature sensor (thermistor)
  2. Damaged sensor wiring

How to fix it — step by step

  1. Turn power off for 10–20 seconds, then back on to clear the code.
  2. The sensor in question is the water temperature thermistor, wired to the Intelli-Vent control at the front of the tank. Before condemning the control, inspect the sensor's wiring run for a chafed, pinched or corroded connection — an open or short in the wire reads exactly like a failed sensor — and reseat its connector at the control.
  3. If the wiring is sound and the code persists, the thermistor is part of the control assembly on these models and the Intelli-Vent control is replaced following the gas control replacement procedure, with all gas connections leak-tested and a full cycle to prove it.
  4. If you hand it over, tell the technician: 13 flashes — water temperature sensor open or shorted — with the sensor wiring already inspected.
  5. Verify after the repair: restore gas, water and power, then open a hot tap and let the heater fire and run for several minutes - the heater should run clean through the whole draw. If it comes back, the repair did not cure it: hand over the point in the sequence where it reappears, because that timing is the diagnosis

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix it

Typical pro repair $228–$1,017

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.