AO Smith Water heater 0 flashes

What this problem usually means

The status light is dark: the pilot is not lit, or the thermopile has not yet reached normal operating temperature, so the electronic gas control has no millivolt power to run on.

Likely causes

  1. Pilot light is out
  2. Thermopile still cold and has not reached operating temperature
  3. No gas supply to the pilot
  4. Tripped resettable thermal switch
  5. Weak pilot flame not heating the thermopile, defective thermopile, or loose wiring connectors

How to fix it — step by step

  1. Turn the gas control valve/thermostat knob to OFF and wait 10 minutes, then relight the pilot following the lighting instructions on the water heater label, holding the knob in at PILOT and clicking the igniter about once per second for up to 90 seconds.
  2. Allow up to 90 seconds of continuous pilot operation for the thermopile to reach normal temperature before expecting the status light to blink.
  3. If the status light does not blink after three lighting attempts, confirm the unit is getting gas.
  4. Remove the outer door, press the reset button on the thermal switch, and replace the outer door, then wait 10 minutes and relight.
  5. Look through the viewport for the pilot flame: if no flame is visible, check the spark igniter and the gas supply to the pilot; if the flame is visible but the light still does not blink after 90 seconds, the pilot is too weak, the thermopile is defective, or a wiring connector is loose.
  6. Check the flame arrestor for blue or black discoloration; discoloration means a flammable vapor incident — do not use the heater and have it inspected, as the entire water heater will require replacement.
  7. Verify the fix: restore gas, water and power, then open a hot tap and let the heater fire and run for several minutes - the heater should run clean through the whole draw. If it comes back, the fault is still present: recheck the step above whose result was borderline, and treat the part that step points to as the one to replace

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix it

Parts run $25–$80Typical pro repair $228–$1,017Fixing it yourself typically saves $148–$992

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manual & model number

Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.

Related AO Smith Water heater problems

See all AO Smith water heater codes & guides →