AO Smith Water heater Intelli-Vent power-vent models 14 flashes

What it should look like on your machine

then it repeats

14 flashes - then the pattern repeats. Count along with your machine and compare.

What this problem usually means

Self-diagnostics detected the flammable vapor sensor is either open or shorted. The control locks out when the sensor resistance it reads is below 5,000 ohms or above 1,700,000 ohms.

Likely causes

  1. Flammable vapor sensor failed open or shorted
  2. Poor connection at the sensor wiring, ignitor plug, or control socket

How to fix it — step by step

  1. Turn power off and check all flammable vapor sensor wiring plus the ignitor assembly plug and socket on the bottom of the control for solid contact; repair or replace worn or damaged parts.
  2. Restore power: if the code clears, run the heater through several cycles to confirm the repair.
  3. With power off, remove the sensor from its bracket on the base ring, disconnect both wires, and measure resistance across its terminals (check on a scale above 1,700,000 ohms and again just above 5,000 ohms).
  4. Replace the flammable vapor sensor if its resistance is below 5,000 ohms or above 1,700,000 ohms.
  5. If sensor resistance is in range and wiring and plug are good, replace the ignitor assembly if its wiring or plug is damaged, otherwise replace the Intelli-Vent control.
  6. Verify after the repair: restore gas, water and power, then open a hot tap and let the heater fire and run for several minutes - the heater should run clean through the whole draw. If it comes back, the repair did not cure it: hand over the point in the sequence where it reappears, because that timing is the diagnosis

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix it

Typical pro repair $228–$1,017

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manual & model number

Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.

Related AO Smith Water heater Intelli-Vent power-vent models problems

See all AO Smith Intelli-Vent power-vent models codes & guides →