Find your code in the list below. Each page explains what the code means, the most likely causes, step-by-step fixes you can do yourself, and the parts that commonly resolve it. 35 codes covered.
Finding your model number: it is on the unit's rating plate.
Tap any code for its full fix — causes, step-by-step checks, and the parts that commonly fix it.
| Code | What it means | Check first | |
| 903 | Combustion abnormality on the air side: the unit is not moving air properly - it cannot pull in enough… | Air inlet blocked or obstructed | › |
| 91 | Incorrect gas type: the unit is being supplied with, or is set up for, the wrong gas type. | Unit supplied natural gas when set up for propane, or vice versa | › |
| 94 | Exhaust temperature too high: on a condensing unit, the exhaust temperature thermistor at the top of the… | Scale buildup in the heat exchanger insulating it and pushing heat into the exhaust | › |
| F76 | Multi-system communication error: units linked in a multi-system (quick-connect) installation are not… | Quick connect cord disconnected or damaged between units | › |
| Won't Turn On | A Noritz tankless heater announces which of its three supplies is missing by what its remote controller does.… | Tripped circuit breaker or a dead outlet — remote display dark | › |
| Code | What it means | Check first | |
| 10 | Combustion abnormality: output drops (BTU drop) and combustion continues after shutdown. The heater detected… | Foreign material such as grease on the burner still burning after shutdown | › |
| 11 | Ignition failure: the unit called for heat but the flame rod did not detect a flame - the burner did not… | Incoming gas pressure out of specification or gas supply off | › |
| 12 | Flame loss during operation: the flame rod stops detecting flame after the burner has lit, so the unit shuts… | Incoming gas pressure low or dropping under load | › |
| 14 | Thermal fuse failure: a major overheat tripped the thermal fuse, which is a one-time safety device - the fuse… | Scale buildup in the heat exchanger from poor water quality insulating the exchanger | › |
| 16 | Abnormally high output water temperature: outlet water temperature rose above the safe limit and the unit… | Scale deposits in the heat exchanger restricting flow and overheating the water | › |
| 20 | High limit switch triggered: the water high limit switch opened on excessive temperature and stopped the… | Scale deposits in the heat exchanger causing overheating | › |
| 29 | Neutralizer water level abnormality: condensate is not draining from the neutralizer, so the water level in… | Condensate/neutralizer drain line clogged or incorrectly routed/sloped | › |
| 31 | Inlet thermistor abnormality: the cold water (inlet) thermistor is reading open, shorted or out of range, so… | Failed inlet (cold water) thermistor | › |
| 32 | Outlet thermistor abnormality: the hot water (outlet) thermistor is reading open, shorted or out of range, so… | Failed outlet (hot water) thermistor | › |
| 33 | Heat exchanger thermistor abnormality: the thermistor monitoring the heat exchanger is reading open, shorted… | Failed heat exchanger thermistor | › |
| 59 | Combustion abnormality with low input BTU: the burner is not getting enough gas/air input to fire at the… | Incoming gas pressure too low | › |
| 61 | Fan motor abnormality: the fan motor is not running at the speed the circuit board commands, or is not… | Failed fan motor | › |
| 65 | Main flow control valve (main servo) abnormality: the main water control servo is blocked or is not… | Blockage/debris in the main servo | › |
| 66 | Bypass flow control valve (bypass servo) abnormality: the bypass water control servo is blocked or is not… | Blockage/debris in the bypass servo | › |
| 70 | Circuit board abnormality: the circuit board faulted, commonly after circuit board reprogramming, and may be… | Circuit board left unprogrammed/incorrectly programmed after replacement | › |
| 71 | Gas valve drive circuit abnormality: the circuit board is not delivering correct voltage to drive the gas… | Unit powered by a modified sine-wave supply (battery backup, solar or generator) | › |
| 72 | Flame rod detection circuit abnormality: flame is being detected without an ignition sequence - a false flame… | Poor unit grounding creating a false flame signal | › |
| 73 | Circuit board setting abnormality: board settings/clips were changed while power was on, or the board… | Connectors or setting clips changed while the unit had power | › |
| 760 | Remote controller transmission abnormality: the heater and its remote controller are not communicating. | Remote cord loose or disconnected between the unit and the remote | › |
| 90 | Combustion abnormality: the air/fuel mixture is wrong - the unit is not burning cleanly or not reaching… | Blockage in the flue vent or intake | › |
| 92 | Neutralizer life cycle warning: the neutralizer is past its usable lifetime and must be replaced - this is… | Neutralizer media exhausted at end of its service life | › |
| 93 | Neutralizer life cycle warning: the neutralizer is past its usable lifetime and must be replaced. | Neutralizer media exhausted at end of its service life | › |
| 99 | Combustion abnormality: the air/fuel mixture is wrong - the unit is not burning cleanly. | Blockage in the flue vent or intake | › |