Noritz Water heater Error Codes

Find your code in the list below. Each page explains what the code means, the most likely causes, step-by-step fixes you can do yourself, and the parts that commonly resolve it. 35 codes covered.

Finding your model number: it is on the unit's rating plate.

Tap any code for its full fix — causes, step-by-step checks, and the parts that commonly fix it.

All models

CodeWhat it meansCheck first
903Combustion abnormality on the air side: the unit is not moving air properly - it cannot pull in enough…Air inlet blocked or obstructed›
91Incorrect gas type: the unit is being supplied with, or is set up for, the wrong gas type.Unit supplied natural gas when set up for propane, or vice versa›
94Exhaust temperature too high: on a condensing unit, the exhaust temperature thermistor at the top of the…Scale buildup in the heat exchanger insulating it and pushing heat into the exhaust›
F76Multi-system communication error: units linked in a multi-system (quick-connect) installation are not…Quick connect cord disconnected or damaged between units›
Won't Turn OnA Noritz tankless heater announces which of its three supplies is missing by what its remote controller does.…Tripped circuit breaker or a dead outlet — remote display dark›

NCC199 / NRC111

CodeWhat it meansCheck first
10Combustion abnormality: output drops (BTU drop) and combustion continues after shutdown. The heater detected…Foreign material such as grease on the burner still burning after shutdown›
11Ignition failure: the unit called for heat but the flame rod did not detect a flame - the burner did not…Incoming gas pressure out of specification or gas supply off›
12Flame loss during operation: the flame rod stops detecting flame after the burner has lit, so the unit shuts…Incoming gas pressure low or dropping under load›
14Thermal fuse failure: a major overheat tripped the thermal fuse, which is a one-time safety device - the fuse…Scale buildup in the heat exchanger from poor water quality insulating the exchanger›
16Abnormally high output water temperature: outlet water temperature rose above the safe limit and the unit…Scale deposits in the heat exchanger restricting flow and overheating the water›
20High limit switch triggered: the water high limit switch opened on excessive temperature and stopped the…Scale deposits in the heat exchanger causing overheating›
29Neutralizer water level abnormality: condensate is not draining from the neutralizer, so the water level in…Condensate/neutralizer drain line clogged or incorrectly routed/sloped›
31Inlet thermistor abnormality: the cold water (inlet) thermistor is reading open, shorted or out of range, so…Failed inlet (cold water) thermistor›
32Outlet thermistor abnormality: the hot water (outlet) thermistor is reading open, shorted or out of range, so…Failed outlet (hot water) thermistor›
33Heat exchanger thermistor abnormality: the thermistor monitoring the heat exchanger is reading open, shorted…Failed heat exchanger thermistor›
59Combustion abnormality with low input BTU: the burner is not getting enough gas/air input to fire at the…Incoming gas pressure too low›
61Fan motor abnormality: the fan motor is not running at the speed the circuit board commands, or is not…Failed fan motor›
65Main flow control valve (main servo) abnormality: the main water control servo is blocked or is not…Blockage/debris in the main servo›
66Bypass flow control valve (bypass servo) abnormality: the bypass water control servo is blocked or is not…Blockage/debris in the bypass servo›
70Circuit board abnormality: the circuit board faulted, commonly after circuit board reprogramming, and may be…Circuit board left unprogrammed/incorrectly programmed after replacement›
71Gas valve drive circuit abnormality: the circuit board is not delivering correct voltage to drive the gas…Unit powered by a modified sine-wave supply (battery backup, solar or generator)›
72Flame rod detection circuit abnormality: flame is being detected without an ignition sequence - a false flame…Poor unit grounding creating a false flame signal›
73Circuit board setting abnormality: board settings/clips were changed while power was on, or the board…Connectors or setting clips changed while the unit had power›
760Remote controller transmission abnormality: the heater and its remote controller are not communicating.Remote cord loose or disconnected between the unit and the remote›
90Combustion abnormality: the air/fuel mixture is wrong - the unit is not burning cleanly or not reaching…Blockage in the flue vent or intake›
92Neutralizer life cycle warning: the neutralizer is past its usable lifetime and must be replaced - this is…Neutralizer media exhausted at end of its service life›
93Neutralizer life cycle warning: the neutralizer is past its usable lifetime and must be replaced.Neutralizer media exhausted at end of its service life›
99Combustion abnormality: the air/fuel mixture is wrong - the unit is not burning cleanly.Blockage in the flue vent or intake›

NCC199CDV

CodeWhat it meansCheck first
41Flow not detected at a secondary unit: in a multi-unit installation of the commercial NCC199CDV, the second…Secondary unit cannot detect flow rate through the system›

NRCP / CB

CodeWhat it meansCheck first
45Water leak detection: the leak sensor at the bottom of the unit, behind the circuit board, detected water…Internal water leak from a component or fitting inside the unit›
67AGM (Air Gas Mixer) abnormality: the AGM, which adjusts the air/gas mixture for proper combustion, is stuck…AGM stuck from excessive buildup in the AGM housing - the motor can no longer move the›

NRCR

CodeWhat it meansCheck first
63Recirculation abnormality: the unit is trying to run the recirculation pump but is not detecting any flow in…Return line filter clogged or water shut-offs closed (new and older installs)›

Premix models

CodeWhat it meansCheck first
C1#Scale buildup alarm: the flashing C1# code (the # is 1-9) means scale has built up in the heat exchanger of a…Scale buildup in the heat exchanger from hard water›

Pro Series

CodeWhat it meansCheck first
10Combustion abnormality warning on premix/Pro Series models: code 10 is the early warning of the more severe…Incorrect installation settings (elevation, vent type, vent length, vent size or common›
79Circuit board (pump control circuit) malfunction: the board's pump control circuit has faulted.Circuit board pump control circuit failure›
Looking for a part?

Once you know the part you need, browse Noritz Water heater replacement parts → The parts shelves are organized by brand, with the parts that actually fix these codes.