Noritz Water heater NCC199 / NRC111 16 Error Code

What the 16 code means

Abnormally high output water temperature: outlet water temperature rose above the safe limit and the unit shut down.

Likely causes

  1. Scale deposits in the heat exchanger restricting flow and overheating the water
  2. Wrong gas type
  3. Manifold pressure set incorrectly

How to fix it — step by step

  1. Confirm the proper gas type is supplied to the unit.
  2. Descale the heat exchanger with descaling equipment and solution to remove scale deposits.
  3. Clean the cold water inlet filter screen.
  4. Have manifold pressure checked with a manometer and adjusted to specification if the code returns after descaling.
  5. Verify the fix: restore gas, water and power, then open a hot tap and let the heater fire and run for several minutes - 16 should stay clear through the whole draw. If it comes back, the fault is still present: recheck the step above whose result was borderline, and treat the part that step points to as the one to replace

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix the 16 code

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.