Noritz Water heater NCC199 / NRC111 12 Error Code
What the 12 code means
Flame loss during operation: the flame rod stops detecting flame after the burner has lit, so the unit shuts down.
Likely causes
- Incoming gas pressure low or dropping under load
- Dirty ignition plug or flame rod
- Obstruction in the venting
- Wrong gas type for the unit
- Poor grounding of the unit
How to fix it — step by step
- Check incoming gas pressure with a manometer, including under flow, against specification — pressure that holds at rest but sags under load is the classic flame-loss cause and is a gas-supply problem, not a rod problem.
- Locate the suspect parts: the ignition plug and flame rod are mounted in the burner assembly at the front of the heat exchanger, in the flame. Access: disconnect power, turn off gas and water, and remove the front cover — the circuit board wiring diagram is behind that front cover, and the burner, rods and pipe-mounted thermistors are all inside it. No tank is opened; this is a tankless cabinet.
- Remove and clean the ignition plug and flame rod with a green scrub pad — do not use sandpaper or emery cloth. A rod that was carbon-fouled and now holds flame through a full cycle was the cause.
- Check the venting for obstructions and clear any blockage; confirm the correct gas type is supplied to the unit; check the unit grounding is secure — poor grounding drops the flame signal mid-cycle.
- Reset and run the unit through a sustained draw: a flame rod that still cannot hold flame detection after cleaning, with pressure, venting, gas type and ground all proven, is replaced — refit in its burner mounting, leads reconnected, cover restored, and prove a long firing cycle.
- Tell the technician: code 12, static and under-load gas pressure readings, and rod condition. What this job involves: burner-area work on a gas appliance and gas-pressure measurement with a manometer.
- Verify after the repair: restore gas, water and power, then open a hot tap and let the heater fire and run for several minutes - 12 should stay clear through the whole draw. If it comes back, the repair did not cure it: hand over the point in the sequence where it reappears, because that timing is the diagnosis
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the Ignition plug.
Shop the Ignition plug at Amazon
Also tied to this fault: Flame rod - Shop at Amazon
Parts that commonly fix the 12 code
- Ignition plugShop at Amazon
- Flame rod$10–$60Shop at Amazon
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.