Noritz Water heater NCC199 / NRC111 12 Error Code

What the 12 code means

Flame loss during operation: the flame rod stops detecting flame after the burner has lit, so the unit shuts down.

Likely causes

  1. Incoming gas pressure low or dropping under load
  2. Dirty ignition plug or flame rod
  3. Obstruction in the venting
  4. Wrong gas type for the unit
  5. Poor grounding of the unit

How to fix it — step by step

  1. Check incoming gas pressure with a manometer, including under flow, against specification — pressure that holds at rest but sags under load is the classic flame-loss cause and is a gas-supply problem, not a rod problem.
  2. Locate the suspect parts: the ignition plug and flame rod are mounted in the burner assembly at the front of the heat exchanger, in the flame. Access: disconnect power, turn off gas and water, and remove the front cover — the circuit board wiring diagram is behind that front cover, and the burner, rods and pipe-mounted thermistors are all inside it. No tank is opened; this is a tankless cabinet.
  3. Remove and clean the ignition plug and flame rod with a green scrub pad — do not use sandpaper or emery cloth. A rod that was carbon-fouled and now holds flame through a full cycle was the cause.
  4. Check the venting for obstructions and clear any blockage; confirm the correct gas type is supplied to the unit; check the unit grounding is secure — poor grounding drops the flame signal mid-cycle.
  5. Reset and run the unit through a sustained draw: a flame rod that still cannot hold flame detection after cleaning, with pressure, venting, gas type and ground all proven, is replaced — refit in its burner mounting, leads reconnected, cover restored, and prove a long firing cycle.
  6. Tell the technician: code 12, static and under-load gas pressure readings, and rod condition. What this job involves: burner-area work on a gas appliance and gas-pressure measurement with a manometer.
  7. Verify after the repair: restore gas, water and power, then open a hot tap and let the heater fire and run for several minutes - 12 should stay clear through the whole draw. If it comes back, the repair did not cure it: hand over the point in the sequence where it reappears, because that timing is the diagnosis

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix the 12 code

Parts run $10–$60Typical pro repair $228–$1,017Fixing it yourself typically saves $168–$1,007

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manual & model number

Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.

Related Noritz Water heater NCC199 / NRC111 error codes