Noritz Water heater NCC199 / NRC111 66 Error Code

What the 66 code means

Bypass flow control valve (bypass servo) abnormality: the bypass water control servo is blocked or is not positioning as commanded.

Likely causes

  1. Blockage/debris in the bypass servo
  2. Failed bypass servo motor/valve

How to fix it — step by step

  1. The bypass water control servo is on the bypass water path at the bottom of the unit, reached with the front cover off — the smaller motorised valve body beside the main servo, with its own electrical connector.
  2. Check the bypass servo for blockage: water off, unit drained at the service valves, the servo's water path inspected for debris or scale and cleared.
  3. Check its operation through a heating cycle: the bypass servo repositions to blend water as outlet temperature demands; one that stalls, hums or never moves with power on its connector has failed.
  4. Replace the bypass servo if it is clear of debris but does not operate: water isolated and drained, connector unplugged, valve body unbolted, new servo fitted with fresh seals, connector back on, unit refilled and purged.
  5. Prove heating cycles at high and low demand with stable temperature and no code 66.
  6. If you hand it over, tell the technician: code 66 — bypass flow control servo abnormality — and whether debris was found in the valve.
  7. Verify after the repair: restore gas, water and power, then open a hot tap and let the heater fire and run for several minutes - 66 should stay clear through the whole draw. If it comes back, the repair did not cure it: hand over the point in the sequence where it reappears, because that timing is the diagnosis

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix the 66 code

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manual & model number

Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.

Related Noritz Water heater NCC199 / NRC111 error codes

See all Noritz NCC199 / NRC111 codes & guides →