Noritz Water heater Won't Turn On
What this problem usually means
A Noritz tankless heater announces which of its three supplies is missing by what its remote controller does. Remote display dark = the control has no power: Noritz units plug into an outlet, and the documented causes are a tripped breaker, a dead outlet, or a blown fuse inside the unit from a voltage problem (a surge can take the fuse and leave a powered outlet with a dead heater). Remote lit but the unit never fires at a tap = it is not seeing flow, or the remote is simply switched off — the remote's ON/OFF is a real control, and a lit-but-off remote is a 'won't turn on' that needs no part. Remote lit with an error code = the unit tried: code 11 is ignition failure (it attempted to light and did not ignite) and code 12 is flame failure — both start with gas supply (valve open, propane in the tank) before any internal part. For a unit that does not attempt to start at all, check the power is on at the unit, and check the isolation valves at the unit are open.
Likely causes
- Tripped circuit breaker or a dead outlet — remote display dark
- Blown internal fuse after a voltage surge or incorrect supply voltage — outlet live, unit still dark
- Remote controller switched off, or its connection to the unit lost
- Isolation valves at the unit not fully open, or flow below the activation minimum — unit never attempts to start
- Gas supply off at the unit or meter, or an empty propane tank — ignition failure (code 11) / flame failure (code 12)
- Failed igniter or flow sensor — gas and flow both proven, unit still will not fire
How to fix it — step by step
- Read the remote controller first. DARK display: go to step 2. LIT but showing OFF / no temperature: press the remote's power button — a switched-off remote is the whole fault more often than any part. LIT with a code: note it; 11 = no ignition, 12 = flame failure — do the gas check in step 4 once, then work the code's page if it returns. LIT, on, no code, never fires: go to step 3
- Power branch: confirm the unit is plugged in and test the outlet with another device; check the breaker and reset it if tripped (trips again = stop and report it). Outlet proven live + breaker holding + remote still dark points inside the unit: the internal fuse is the documented surge victim, and a fuse that blew once from a surge is a one-time replacement — but opening the unit is technician work on a gas appliance, so the pinpoint to hand over is 'supply proven at the outlet, unit dark — internal fuse or control board' → Shop the internal fuse at Amazon → Shop the control board at Amazon
- Flow branch: the first checks for a unit that does not attempt to start are power at the unit and the isolation valves at the unit fully open. Open both valves fully, then run one hot tap FULLY open (below the activation flow the unit correctly does nothing). Still no attempt: the inlet water filter/screen at the cold inlet is the next suspect — close the valves, clean it, reopen and retest. Clean filter + full flow + valves open + no attempt = the flow sensor is not reporting; that is the terminal pinpoint
- Gas branch: confirm the gas isolation valve at the unit AND at the meter are fully open, and on propane, that the tank has gas. Then open a hot tap fully: fan + ignition clicking with a code 11 means it tried and no flame was established — with gas proven at the valves, the igniter is the lead internal suspect. If the unit starts then shuts down immediately, Noritz's checks are: power still on, gas valves fully open, and the hot tap opened fully — a partly-open tap starving flow imitates a gas fault
- Reset once: turn the remote off and on (or cycle power at the outlet/breaker) to clear a transient lockout, then retest at full flow. A code that returns at once is a standing fault — hand the code and the branch results (power proven, valves open, filter clean) to the technician; that combination is the diagnosis, and repeated resets add nothing
- Verify under load: burner fires at one full tap, temperature reaches the setpoint and holds through a long draw, and the remote stays code-free — then a second tap confirms it modulates instead of dropping out
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the internal fuse.
Shop the internal fuse at Amazon
Also tied to this fault: remote controller - Shop at Amazon; inlet filter screen - Shop at Amazon; flow sensor - Shop at Amazon; igniter - Shop at Amazon; control board - Shop at Amazon
Parts that commonly fix it
- internal fuseShop at Amazon
- remote controllerShop at Amazon
- inlet filter screen$5–$20Shop at Amazon
- flow sensorShop at Amazon
- igniterShop at Amazon
- control board$100–$300Shop at Amazon
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.