Noritz NCC199 / NRC111 Error Codes

Find your code in the list below. Each page explains what the code means, the most likely causes, step-by-step fixes you can do yourself, and the parts that commonly resolve it. 23 codes covered.

Tap any code for its full fix — causes, step-by-step checks, and the parts that commonly fix it.

CodeWhat it meansCheck first
10Combustion abnormality: output drops (BTU drop) and combustion continues after shutdown. The heater detected…Foreign material such as grease on the burner still burning after shutdown›
11Ignition failure: the unit called for heat but the flame rod did not detect a flame - the burner did not…Incoming gas pressure out of specification or gas supply off›
12Flame loss during operation: the flame rod stops detecting flame after the burner has lit, so the unit shuts…Incoming gas pressure low or dropping under load›
14Thermal fuse failure: a major overheat tripped the thermal fuse, which is a one-time safety device - the fuse…Scale buildup in the heat exchanger from poor water quality insulating the exchanger›
16Abnormally high output water temperature: outlet water temperature rose above the safe limit and the unit…Scale deposits in the heat exchanger restricting flow and overheating the water›
20High limit switch triggered: the water high limit switch opened on excessive temperature and stopped the…Scale deposits in the heat exchanger causing overheating›
29Neutralizer water level abnormality: condensate is not draining from the neutralizer, so the water level in…Condensate/neutralizer drain line clogged or incorrectly routed/sloped›
31Inlet thermistor abnormality: the cold water (inlet) thermistor is reading open, shorted or out of range, so…Failed inlet (cold water) thermistor›
32Outlet thermistor abnormality: the hot water (outlet) thermistor is reading open, shorted or out of range, so…Failed outlet (hot water) thermistor›
33Heat exchanger thermistor abnormality: the thermistor monitoring the heat exchanger is reading open, shorted…Failed heat exchanger thermistor›
59Combustion abnormality with low input BTU: the burner is not getting enough gas/air input to fire at the…Incoming gas pressure too low›
61Fan motor abnormality: the fan motor is not running at the speed the circuit board commands, or is not…Failed fan motor›
65Main flow control valve (main servo) abnormality: the main water control servo is blocked or is not…Blockage/debris in the main servo›
66Bypass flow control valve (bypass servo) abnormality: the bypass water control servo is blocked or is not…Blockage/debris in the bypass servo›
70Circuit board abnormality: the circuit board faulted, commonly after circuit board reprogramming, and may be…Circuit board left unprogrammed/incorrectly programmed after replacement›
71Gas valve drive circuit abnormality: the circuit board is not delivering correct voltage to drive the gas…Unit powered by a modified sine-wave supply (battery backup, solar or generator)›
72Flame rod detection circuit abnormality: flame is being detected without an ignition sequence - a false flame…Poor unit grounding creating a false flame signal›
73Circuit board setting abnormality: board settings/clips were changed while power was on, or the board…Connectors or setting clips changed while the unit had power›
760Remote controller transmission abnormality: the heater and its remote controller are not communicating.Remote cord loose or disconnected between the unit and the remote›
90Combustion abnormality: the air/fuel mixture is wrong - the unit is not burning cleanly or not reaching…Blockage in the flue vent or intake›
92Neutralizer life cycle warning: the neutralizer is past its usable lifetime and must be replaced - this is…Neutralizer media exhausted at end of its service life›
93Neutralizer life cycle warning: the neutralizer is past its usable lifetime and must be replaced.Neutralizer media exhausted at end of its service life›
99Combustion abnormality: the air/fuel mixture is wrong - the unit is not burning cleanly.Blockage in the flue vent or intake›

All Noritz water heater models & codes →

Looking for a part?

Once you know the part you need, browse Noritz NCC199 / NRC111 replacement parts → The parts shelves are organized by brand, with the parts that actually fix these codes.