Noritz Water heater 94 Error Code

What the 94 code means

Exhaust temperature too high: on a condensing unit, the exhaust temperature thermistor at the top of the exhaust box shut the unit down because exhaust temperature rose above its limit. Display-window units show this as 941 (warning, output restricted) or 942 (shutdown).

Likely causes

  1. Scale buildup in the heat exchanger insulating it and pushing heat into the exhaust
  2. Restriction in the exhaust or intake venting
  3. Dirty fan unable to move enough air
  4. Incorrect manifold gas pressures causing abnormal combustion

How to fix it — step by step

  1. Descale the heat exchanger — scale is the most common cause; dark grey colouring on the copper heat exchanger surface is a sign of scale. Flush through the isolation valves with a pump and descaling solution until the return runs clear.
  2. Check the exhaust and intake venting for restrictions and make sure vent termination screens are clear of debris.
  3. Clean the fan if it has excessive buildup: the fan is at the bottom of the cabinet (front cover off) — power off, and clear the buildup from its housing and wheel without bending the wheel.
  4. Have manifold gas pressures checked and adjusted with a digital manometer if they are out of specification — gas pressure adjustment is technician work.
  5. Only if scale, venting, fan and pressures are all correct does the code turn on its own sensor: the exhaust temperature thermistor at the top of the exhaust box (front cover off, at the exhaust outlet) — a thermistor reading out of its expected range for the measured exhaust temperature is replaced (connector off, sensor unthreaded, new sensor fitted).
  6. Prove a full high-demand cycle with no 941/942 warning or shutdown.
  7. If you hand it over, tell the technician: code 94 — exhaust temperature too high — and the unit's descale history.
  8. Verify after the repair: restore gas, water and power, then open a hot tap and let the heater fire and run for several minutes - 94 should stay clear through the whole draw. If it comes back, the repair did not cure it: hand over the point in the sequence where it reappears, because that timing is the diagnosis

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix the 94 code

Parts run $25–$80Typical pro repair $228–$1,017Fixing it yourself typically saves $148–$992

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manufacturer documentation

Manual & model number

Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.

Related Noritz Water heater error codes

See all Noritz water heater codes & guides →