Noritz Water heater 94 Error Code
What the 94 code means
Exhaust temperature too high: on a condensing unit, the exhaust temperature thermistor at the top of the exhaust box shut the unit down because exhaust temperature rose above its limit. Display-window units show this as 941 (warning, output restricted) or 942 (shutdown).
Likely causes
- Scale buildup in the heat exchanger insulating it and pushing heat into the exhaust
- Restriction in the exhaust or intake venting
- Dirty fan unable to move enough air
- Incorrect manifold gas pressures causing abnormal combustion
How to fix it — step by step
- Descale the heat exchanger — scale is the most common cause; dark grey colouring on the copper heat exchanger surface is a sign of scale. Flush through the isolation valves with a pump and descaling solution until the return runs clear.
- Check the exhaust and intake venting for restrictions and make sure vent termination screens are clear of debris.
- Clean the fan if it has excessive buildup: the fan is at the bottom of the cabinet (front cover off) — power off, and clear the buildup from its housing and wheel without bending the wheel.
- Have manifold gas pressures checked and adjusted with a digital manometer if they are out of specification — gas pressure adjustment is technician work.
- Only if scale, venting, fan and pressures are all correct does the code turn on its own sensor: the exhaust temperature thermistor at the top of the exhaust box (front cover off, at the exhaust outlet) — a thermistor reading out of its expected range for the measured exhaust temperature is replaced (connector off, sensor unthreaded, new sensor fitted).
- Prove a full high-demand cycle with no 941/942 warning or shutdown.
- If you hand it over, tell the technician: code 94 — exhaust temperature too high — and the unit's descale history.
- Verify after the repair: restore gas, water and power, then open a hot tap and let the heater fire and run for several minutes - 94 should stay clear through the whole draw. If it comes back, the repair did not cure it: hand over the point in the sequence where it reappears, because that timing is the diagnosis
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the Descaling solution.
Shop the Descaling solution at Amazon
Also tied to this fault: Exhaust temperature thermistor - Shop at Amazon
Parts that commonly fix the 94 code
- Descaling solutionShop at Amazon
- Exhaust temperature thermistor$25–$80Shop at Amazon
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.