Noritz Water heater NCC199 / NRC111 71 Error Code

What the 71 code means

Gas valve drive circuit abnormality: the circuit board is not delivering correct voltage to drive the gas solenoid valve.

Likely causes

  1. Unit powered by a modified sine-wave supply (battery backup, solar or generator) disturbing the drive voltage
  2. Failed circuit board gas valve output
  3. Gas valve solenoid fault

How to fix it — step by step

  1. Check whether the unit is running on a modified sine-wave voltage supply (battery backup, solar power or generator) and power it from a clean utility supply instead — a distorted supply disturbing the drive voltage is the first documented cause, and it is eliminated by changing the supply, not a part.
  2. The circuit board is inside the front of the cabinet (front cover off); the gas valve is at the bottom of the unit on the gas line, its solenoid connector wired back to the board.
  3. Check the voltage output from the circuit board to the gas valve with a voltmeter during an ignition attempt: output absent or incorrect condemns the board's gas valve drive circuit; output correct with the valve not operating condemns the gas valve solenoid.
  4. Replace what the test condemns: the circuit board (photograph connectors, transfer one at a time, settings matched to the model) or the gas valve (gas off, its union and connector broken, new valve fitted and leak-tested — gas-line work).
  5. Prove a full ignition and heating cycle with no code 71.
  6. If you hand it over, tell the technician: code 71 — gas valve drive circuit abnormality — and whether the unit is on any backup or generator supply.
  7. Verify after the repair: restore gas, water and power, then open a hot tap and let the heater fire and run for several minutes - 71 should stay clear through the whole draw. If it comes back, the repair did not cure it: hand over the point in the sequence where it reappears, because that timing is the diagnosis

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix the 71 code

Typical pro repair $228–$1,017

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manual & model number

Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.

Related Noritz Water heater NCC199 / NRC111 error codes

See all Noritz NCC199 / NRC111 codes & guides →