Noritz Water heater NCC199 / NRC111 71 Error Code
What the 71 code means
Gas valve drive circuit abnormality: the circuit board is not delivering correct voltage to drive the gas solenoid valve.
Likely causes
- Unit powered by a modified sine-wave supply (battery backup, solar or generator) disturbing the drive voltage
- Failed circuit board gas valve output
- Gas valve solenoid fault
How to fix it — step by step
- Check whether the unit is running on a modified sine-wave voltage supply (battery backup, solar power or generator) and power it from a clean utility supply instead — a distorted supply disturbing the drive voltage is the first documented cause, and it is eliminated by changing the supply, not a part.
- The circuit board is inside the front of the cabinet (front cover off); the gas valve is at the bottom of the unit on the gas line, its solenoid connector wired back to the board.
- Check the voltage output from the circuit board to the gas valve with a voltmeter during an ignition attempt: output absent or incorrect condemns the board's gas valve drive circuit; output correct with the valve not operating condemns the gas valve solenoid.
- Replace what the test condemns: the circuit board (photograph connectors, transfer one at a time, settings matched to the model) or the gas valve (gas off, its union and connector broken, new valve fitted and leak-tested — gas-line work).
- Prove a full ignition and heating cycle with no code 71.
- If you hand it over, tell the technician: code 71 — gas valve drive circuit abnormality — and whether the unit is on any backup or generator supply.
- Verify after the repair: restore gas, water and power, then open a hot tap and let the heater fire and run for several minutes - 71 should stay clear through the whole draw. If it comes back, the repair did not cure it: hand over the point in the sequence where it reappears, because that timing is the diagnosis
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the Gas valve.
Also tied to this fault: Circuit board - Shop at Amazon
Parts that commonly fix the 71 code
- Gas valve$115–$500Shop at Amazon
- Circuit board$100–$300Shop at Amazon
- Tools for this job, if you need them$15–$65
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.