Noritz Water heater NCC199 / NRC111 33 Error Code

What the 33 code means

Heat exchanger thermistor abnormality: the thermistor monitoring the heat exchanger is reading open, shorted or out of range.

Likely causes

  1. Failed heat exchanger thermistor
  2. Loose or damaged thermistor wiring/connector

How to fix it — step by step

  1. Locate the suspect part: the heat exchanger thermistor is clipped onto the heat exchanger pipework inside the cabinet, with its lead running to the circuit board (the Noritz tech sheet lists the cold-water thermistor checkpoint at connector CN63 on the board). Access: disconnect power, turn off gas and water, and remove the front cover — the circuit board wiring diagram is behind that front cover, and the burner, rods and pipe-mounted thermistors are all inside it. No tank is opened; this is a tankless cabinet.
  2. Check the thermistor's connector seating at the board and at the sensor and inspect the lead for damage — reseat or repair the connector/wiring if loose or damaged, restore power and retest: a cleared code was a connection fault.
  3. Measure the thermistor resistance against the temperature chart for the actual water temperature at that pipe: resistance in specification means the sensor is reading correctly and the fault is in the wiring/board path; resistance open, shorted or out of specification condemns the thermistor itself.
  4. Replace the thermistor if its resistance is out of specification: unclip it from the heat exchanger pipework, disconnect its lead, fit the new thermistor tight to the pipe so it senses true pipe temperature, reconnect, refit the front cover, and prove a heating cycle with plausible temperature readings and no repeat code.
  5. Tell the technician: code 33, the resistance measured and the actual pipe temperature it was measured at. What this job involves: low-voltage sensor work inside the cabinet — power disconnected while connectors are handled.
  6. Verify after the repair: restore gas, water and power, then open a hot tap and let the heater fire and run for several minutes - 33 should stay clear through the whole draw. If it comes back, the repair did not cure it: hand over the point in the sequence where it reappears, because that timing is the diagnosis

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix the 33 code

Parts run $300–$900Typical pro repair $228–$1,017
  • Heat exchanger thermistor$300–$900Shop at Amazon
  • Tools for this job, if you need them$15–$65

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.