Noritz Water heater NCC199 / NRC111 59 Error Code

What the 59 code means

Combustion abnormality with low input BTU: the burner is not getting enough gas/air input to fire at the required rate.

Likely causes

  1. Incoming gas pressure too low
  2. Blockage in the venting
  3. Debris in the fan motor or burner chamber
  4. Unit not adjusted for high elevation

How to fix it — step by step

  1. Work Noritz's four checkpoints for code 59 (combustion abnormality, low input BTU) in order — the list is from Noritz's NCC199/NRC111 error-code sheet, which names a screwdriver and a manometer as the tools, so the internal checks are a technician's. The parts involved are the gas supply to the unit, the venting, and the fan motor and burner chamber inside the cabinet behind the front cover.
  2. Check incoming gas pressure with a manometer against the unit's specification: pressure below specification is a complete result — the burner is starved of input, and the fix is at the gas supply/valve, not inside the burner. Pressure in specification moves the diagnosis to the air side.
  3. Check the venting for blockage and clear any blockage found: a blocked vent restricts combustion air/exhaust the same way low gas restricts fuel, so clear it and test-fire before opening the unit further.
  4. Inspect the fan motor and burner chamber for debris and clean them out: debris found and removed, followed by a clean test-fire, was the restriction; a fan that cannot move air after cleaning is serviced/replaced.
  5. Adjust the unit for high elevation if it is installed at altitude (Noritz's fourth checkpoint — an unadjusted unit at altitude is chronically short of input).
  6. Reset by disconnecting power and test-fire the unit on a hot-water demand: 59 staying clear under load confirms the checkpoint that was corrected was the cause; 59 returning with gas pressure, venting, fan/burner and elevation all proven leaves the gas supply/valve to be serviced, which is the pinpoint to hand the technician.

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix the 59 code

No specific replacement part is documented for this fault. If the checks above do not clear it, your water heater likely needs to be disassembled and an internal part replaced - and since the manufacturer publishes no procedure for that, it is the point where most owners hand it to a repair shop.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manual & model number

Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.

Related Noritz Water heater NCC199 / NRC111 error codes

See all Noritz NCC199 / NRC111 codes & guides →