Noritz Water heater NCC199 / NRC111 760 Error Code
What the 760 code means
Remote controller transmission abnormality: the heater and its remote controller are not communicating.
Likely causes
- Remote cord loose or disconnected between the unit and the remote
- More than one remote connected to the heater/system
- Damaged remote wiring
How to fix it — step by step
- Disconnect power to reset the unit, then restore it - a one-off communication glitch clears here and does not come back.
- Make sure only one remote controller is connected to the heater (system) - a second remote on the line produces this abnormality by itself.
- Check the remote cord at both ends: it plugs into the back of the remote controller at one end and into a terminal inside the unit at the other - disconnect power and remove the unit's front cover to reach the unit end. Reseat both connections securely. Communication returning after a reseat confirms a loose connection was the fault.
- If the connections are tight at both ends and 760 returns, the cord itself is damaged (pinched or cut along its run) - replace the remote controller cord and verify the remote display and controls respond. → Shop the remote controller cord at Amazon
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
Then the likely broken part is the Remote controller cord.
Parts that commonly fix the 760 code
- Remote controller cordShop at Amazon
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.