What the 93 code means

Neutralizer life cycle warning: the neutralizer is past its usable lifetime and must be replaced.

Likely causes

  1. Neutralizer media exhausted at end of its service life

How to fix it — step by step

  1. The neutralizer is the cylindrical canister at the bottom of this condensing unit, in the condensate drain path; code 93 is the same end-of-life warning as 92 at its later stage — the media is past usable lifetime and must be replaced. → Shop the neutralizer at Amazon
  2. Replace the neutralizer: power off, condensate drained, canister unclipped/unthreaded from its fittings, new neutralizer or fresh media fitted, drain path reconnected and leak-checked on a run.
  3. Reset the burner timer after the neutralizer is replaced, or the warning will remain.
  4. Prove a heating cycle with normal condensate drainage and no code 93.
  5. If you hand it over, tell the technician: code 93 — neutralizer past usable lifetime.
  6. Verify after the repair: restore gas, water and power, then open a hot tap and let the heater fire and run for several minutes - 93 should stay clear through the whole draw. If it comes back, the repair did not cure it: hand over the point in the sequence where it reappears, because that timing is the diagnosis

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix the 93 code

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manual & model number

Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.

Related Noritz Water heater NCC199 / NRC111 error codes

See all Noritz NCC199 / NRC111 codes & guides →