Noritz Water heater NRCP / CB 67 Error Code

What the 67 code means

AGM (Air Gas Mixer) abnormality: the AGM, which adjusts the air/gas mixture for proper combustion, is stuck and cannot move through its range.

Likely causes

  1. AGM stuck from excessive buildup in the AGM housing - the motor can no longer move the part
  2. AGM wiring harness loose, damaged or not fully seated

How to fix it — step by step

  1. Cut electrical power, wait 20 seconds and restore power - the AGM should attempt to calibrate itself by rotating through its full range of motion shortly after power returns.
  2. Check the wiring to and from the AGM is complete, undamaged and fully connected, with the harness connector fully seated and no wires pulled out.
  3. Clean or replace the Air Gas Mixer if the housing buildup prevents movement. → Shop the air gas mixer (agm) at Amazon
  4. Verify after the repair: restore gas, water and power, then open a hot tap and let the heater fire and run for several minutes - 67 should stay clear through the whole draw. If it comes back, the repair did not cure it: hand over the point in the sequence where it reappears, because that timing is the diagnosis

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix the 67 code

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manufacturer documentation

Manual & model number

Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.

Related Noritz Water heater NRCP / CB error codes

See all Noritz NRCP / CB codes & guides →