Noritz Water heater NRCP / CB 67 Error Code
What the 67 code means
AGM (Air Gas Mixer) abnormality: the AGM, which adjusts the air/gas mixture for proper combustion, is stuck and cannot move through its range.
Likely causes
- AGM stuck from excessive buildup in the AGM housing - the motor can no longer move the part
- AGM wiring harness loose, damaged or not fully seated
How to fix it — step by step
- Cut electrical power, wait 20 seconds and restore power - the AGM should attempt to calibrate itself by rotating through its full range of motion shortly after power returns.
- Check the wiring to and from the AGM is complete, undamaged and fully connected, with the harness connector fully seated and no wires pulled out.
- Clean or replace the Air Gas Mixer if the housing buildup prevents movement. → Shop the air gas mixer (agm) at Amazon
- Verify after the repair: restore gas, water and power, then open a hot tap and let the heater fire and run for several minutes - 67 should stay clear through the whole draw. If it comes back, the repair did not cure it: hand over the point in the sequence where it reappears, because that timing is the diagnosis
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the Air Gas Mixer (AGM).
Parts that commonly fix the 67 code
- Air Gas Mixer (AGM)Shop at Amazon
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.