Noritz Water heater NCC199 / NRC111 11 Error Code

What the 11 code means

Ignition failure: the unit called for heat but the flame rod did not detect a flame - the burner did not light.

Likely causes

  1. Incoming gas pressure out of specification or gas supply off
  2. Dirty ignition plug or flame rod
  3. Obstruction in the venting blocking combustion air
  4. Wrong gas type for the unit
  5. Poor grounding of the unit

How to fix it — step by step

  1. Verify the main gas supply valve is open and check incoming gas pressure with a manometer against the rating plate specification — low or absent pressure is a supply fault, not a parts fault.
  2. Locate the suspect parts: the ignition plug and flame rod are mounted in the burner assembly at the front of the heat exchanger, side by side in the flame. Access: disconnect power, turn off gas and water, and remove the front cover — the circuit board wiring diagram is behind that front cover, and the burner, rods and pipe-mounted thermistors are all inside it. No tank is opened; this is a tankless cabinet.
  3. Remove and clean the ignition plug and flame rod with a green scrub pad — the Noritz list specifically says do not use sandpaper or emery cloth, which damages the rod surface. Carbon fouling found and cleaned, followed by a successful ignition, means fouling was the cause.
  4. Check the venting and intake for obstructions and clear any blockage; confirm the gas type supplied matches the unit (natural gas vs propane); check the unit grounding connection is secure — a poor ground breaks flame sensing even with a clean rod.
  5. Reset and call for heat: spark with no flame points back to gas supply/valve; flame that lights but is not detected points to the flame rod circuit. If there is still no flame detection, replace the ignition plug/flame rod assembly — refit the rods in their burner mounting with their leads reconnected, restore the cover, and prove repeated ignition cycles. → Shop the ignition plug at Amazon → Shop the flame rod at Amazon
  6. Tell the technician: code 11, incoming gas pressure reading, rod condition before cleaning, and whether spark/flame were seen. What this job involves: burner-area work on a gas appliance and gas-pressure measurement with a manometer.
  7. Verify after the repair: restore gas, water and power, then open a hot tap and let the heater fire and run for several minutes - 11 should stay clear through the whole draw. If it comes back, the repair did not cure it: hand over the point in the sequence where it reappears, because that timing is the diagnosis

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix the 11 code

Typical pro repair $228–$1,017

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manual & model number

Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.

Related Noritz Water heater NCC199 / NRC111 error codes

See all Noritz NCC199 / NRC111 codes & guides →