Noritz Water heater NCC199 / NRC111 11 Error Code
What the 11 code means
Ignition failure: the unit called for heat but the flame rod did not detect a flame - the burner did not light.
Likely causes
- Incoming gas pressure out of specification or gas supply off
- Dirty ignition plug or flame rod
- Obstruction in the venting blocking combustion air
- Wrong gas type for the unit
- Poor grounding of the unit
How to fix it — step by step
- Verify the main gas supply valve is open and check incoming gas pressure with a manometer against the rating plate specification — low or absent pressure is a supply fault, not a parts fault.
- Locate the suspect parts: the ignition plug and flame rod are mounted in the burner assembly at the front of the heat exchanger, side by side in the flame. Access: disconnect power, turn off gas and water, and remove the front cover — the circuit board wiring diagram is behind that front cover, and the burner, rods and pipe-mounted thermistors are all inside it. No tank is opened; this is a tankless cabinet.
- Remove and clean the ignition plug and flame rod with a green scrub pad — the Noritz list specifically says do not use sandpaper or emery cloth, which damages the rod surface. Carbon fouling found and cleaned, followed by a successful ignition, means fouling was the cause.
- Check the venting and intake for obstructions and clear any blockage; confirm the gas type supplied matches the unit (natural gas vs propane); check the unit grounding connection is secure — a poor ground breaks flame sensing even with a clean rod.
- Reset and call for heat: spark with no flame points back to gas supply/valve; flame that lights but is not detected points to the flame rod circuit. If there is still no flame detection, replace the ignition plug/flame rod assembly — refit the rods in their burner mounting with their leads reconnected, restore the cover, and prove repeated ignition cycles. → Shop the ignition plug at Amazon → Shop the flame rod at Amazon
- Tell the technician: code 11, incoming gas pressure reading, rod condition before cleaning, and whether spark/flame were seen. What this job involves: burner-area work on a gas appliance and gas-pressure measurement with a manometer.
- Verify after the repair: restore gas, water and power, then open a hot tap and let the heater fire and run for several minutes - 11 should stay clear through the whole draw. If it comes back, the repair did not cure it: hand over the point in the sequence where it reappears, because that timing is the diagnosis
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the Ignition plug.
Shop the Ignition plug at Amazon
Also tied to this fault: Flame rod - Shop at Amazon
Parts that commonly fix the 11 code
- Ignition plugShop at Amazon
- Flame rod$10–$60Shop at Amazon
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.